background image

Page 11 of 1

3

Trouble Shooting

PROBLEM

SOLUTION

Elec

trode and burners

 are wet

Igniter battery is dead or 

backwards

Igniter Pin cracked or broken 

- sparks a crack

Wipe dry with cloth.
Check that the AAA battery is inserted correctly in 

the igniter or replace the battery.Make sure the 

plastic wrap on the battery has been removed

.

Please contact Living source to request the

 

parts.

Residue on Igniter Pin

No Gas Flow

Check for residue on the igniter pin or 

Thermocouple. If dirty,thoroughly clean the area.

Check that the electronic Ignitor Cap is tightly 

fitted to the spring.If loose,please adjust the

spring accordingly.

Check if the LP gas tank is empty. If empty,

replace and refill. If the propane tank is not empty, 

refer to Problem: Sudden drop in gas flow on the 

following page.

Coupling nut and regulator not 

fully connected

Turn  the  coupling  nut  about  one  half  to  three 

fourths a turn, until you feel a solid stop.

 

Do not 

use tools, tighten by hand only.

Obstruction of gas flow

Check for bent or kinked hose.

Spider webs or insect nest in 

the venturi

Clean the venturi.

Burner ports clogged or 

blocked

Reference Problem: Irregular flame pattern on the 

following page. Clean the burner ports as 

described there.

Hose from gas fire table 

is

 pinched

Make sure the hose is not pinched between the 

fire table and the source of the gas.

Flame is being obstructed at 

burner ports or mixing chamber 

of the burn tube is blocked or 

obstructed

Make sure that the gas ports on the burner are 

free of any lava rocks/fire glass so that the 

flame can flow naturally.Clear out the mixing 

chamber located before the Venturi.

Out of Gas

Check for gas in the LP gas tank.

Excess flow safety device

 may 

have been activated

Turn control knob to OFF, wait 30 seconds and 

light outdoor fire table.if flames are still too low, 

reset the excessive flow safety device by turning 

off the control knob and LP gas tank valve. 

Disconnect regulator. Turn burner control knob to 

HIGH. Wait at least 5 minutes. Turn burner control 

knob off. Reconnect regulator and perform a leak 

check at tank connection. Turn LP gas tank valve 

on slowly, wait 30 seconds and then light outdoor 

fire table

.

Irregular flame pattern, flame

 does 

not run the full length of the burner

Burner ports are clogged or 

blocked

Clean  burner  ports.Do  this  by  inserting  a 

paperclip  into  each  of  the  burner  ports  to 

ensure  they  are  not  clogged.

WARNING: Make  sure  burner  is  not  on,  and 

has  had sufficient time to cool before touching it.

High or gusting winds

Increase flame to HIGH setting.

Low on LP gas

Replace or refill LP gas tank.

Excess flow valve tripped

Refer to Problem: Sudden drop in gas flow

.

Flame seems to lose heat when 

burning in cold weather

 - 

temperature below 50°F

Ice has built up on the outside 

of the LP gas tank because 

the vaporization process is too 

low

Turn the control knob and the LP gas tank to OFF. 

Replace with a spare LP gas tank and resume 

burning. Store the spare LP gas tank in a well 

ventilated area, away from children.

Burner will not light using igniter

Burner will not light with match

The fire table emits a lot of

 

black smoke when in use

Sudden drop in gas flow, or a

 

reduced flame height

Flame blow out

CAUSE

Содержание TM21RT56FPT1

Страница 1: ...store please visit sunvilla com or contact our Customer Service Department at cs sunvillahome com or call 1 888 690 9800 8am 5pm PST Monday Friday IMPORTANT RETAIN FOR FUTURE REFERENCE READ CAREFULLY THE ITEM IS INTENDED FOR OUTDOOR DOMESTIC USE ONLY NOT FOR COMMERCIAL USE ITM ART TM21RT56FPT1 ...

Страница 2: ...CONTENTS Warnings 1 4 Assembly 6 7 Operation 8 9 Maintenance Storage 10 Trouble Shooting 11 12 Warranty Information 13 Diagram 5 ...

Страница 3: ...llowed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you For Outdoor Use Only Never use in the unventilated or enclosed areas DANGER IF YOU SMELL GAS Shut off gas to the appliance Extinguish any open flame If odor contin...

Страница 4: ... tanks of the U S Department of Transportation or the National Standard of Canada CAN CSA B339 LP gas tanks spheres and tubes for Transportation of Dangerous Goods and Commission Discontinue use if any part of the propane tank is damaged Rust and dents may be hazardous and should be inspected by a gas supplier The installation of this unit must adhere to local codes or either the National Fuel Gas...

Страница 5: ...t enlarge valve orifices or burner ports when cleaning the valve or Do not light or use gas unit if lava rocks are wet Ensure lava rocks are length of time Remove the PVC Cover from the firebowl before opening the appliance Do not pour water into the firebowl Do not use this firebowl if any part has been under water Do not use this firebowl on vehicles or boats Always operate the Clean the battery...

Страница 6: ...goes out while burning turn the gas valve off Wait 5 minutes before repeating the initial lighting procedure Once you have a flame started hold down the control knob for 1 minute Inspect all elements of this heating unit before each use If there is damage the burner must be replaced Keep the hose out from any pathways to eliminate any accidental damage if external tank Installation and repair shou...

Страница 7: ... 13 1 2 3 4 2 box 1 pc 1 pc 1 pc 5 1 pc 6 1 pc 7 1 pc 8 1 pc 9 1 pc Lava Rocks Battery AAA PVC Cover Tank Seat Burner Body Screen Burner Control Knob Electric Ignition Parts Diagram Parts List 8 7 6 9 1 2 3 4 5 ...

Страница 8: ...op of the firebowl Step 3 Check each part before using the product Make sure the gas supply system is turned OFF before assembling Step 4 Put the gas tank in the metal tank seat Make sure the gas tank sits on the metal seat completely Turn the wing screw on the outer part of metal seat clockwise to secure the gas tank tightly Assembly Instructions Step 2 1 Turn the firebowl heads up on a flat grou...

Страница 9: ...va rock into the fire bowl Always keep Ignition SCREEN visible Connect the Pressure Regulating Valve to the gas tank Step 8 Turn the cylinder valve clockwise to close the gas supply on the gas tank Assembly Instructions Step 9 Screw Regulator Coupling clockwise by hand only Make sure it is fastened Step 6 Place the lava rock averagely in the fire bowl on the top of the firebowl NOTICE Do not place...

Страница 10: ... is discovered turn the gas valve off disconnect propane gas tank and do not use the appliance until the leak is repaired After turning the gas supply if bubbles occur on any connection there may be a leak Do not use the appliance if any part has been submerged under water Immediately call a qualified service technician to inspect the unit and to replace the part Do not use the heating unit withou...

Страница 11: ...Ignitor Continue to push and hold the Control Knob for 45 seconds 5 If ignition does NOT immediately take place in seconds push and turn the Control Knob clockwise to OFF Wait 5 minutes then repeat the lighting procedure as above 6 If the burner does not ignite with the valve open gas will continue to flow out of the burner and could accidently ignite with risk of injury HOW TO EXTINGUISH Push the...

Страница 12: ... down Wipe down with a soft cloth Harsh weather conditions may cause stubborn stains discoloration and possibly rust pitting Permanent damage may occur if powder or solvent comes in contact with painted or plastic components on this heating unit Keep the heating unit stored away from direct sunlight If storing this unit inside disconnect the propane gas tank from the gas valve Not using manufactur...

Страница 13: ... of any lava rocks fire glass so that the flame can flow naturally Clear out the mixing chamber located before the Venturi Out of Gas Check for gas in the LP gas tank Excess flow safety device may have been activated Turn control knob to OFF wait 30 seconds and light outdoor fire table if flames are still too low reset the excessive flow safety device by turning off the control knob and LP gas tank...

Страница 14: ...ve with the silver backing Once this has been done please test the unit You may have to reset the gas valve once again as the safety mechanism may have been set off by the new components introduced Resetting Your Gas Valve Completely detach the propane tank from the table Do not forget to turn the propane tank valve down Turn the heat knob to high and leave it on that setting for about two to thre...

Страница 15: ...mer Defects or damage caused by the use of other than genuine parts are not covered under this warranty This warranty shall be effective from the date of purchase as shown in the purchase receipt The manufacturer warranty will be voided by and manufacturer disclaims any responsibility for the following actions but not limited Modification of the unit and or components including the gas valve assem...

Отзывы: