Maintenance & Service Tasks
Inspect
Inspect
Burner Assembly
Gas Hose
with Regulator
Burner Ignition
and Operation
Remove decorative glass and examine burner. Vacuum and wipeout as needed.
Use caution when cleaning these areas.
Inspect for warping and corrosion. Repair as necessary.
Check the hose connecting the LP gas cylinder to ensure it is not damaged.
Replace as necessary.
Verify air shutter area is clean.
Verify all gas connections are tight and leak-free.
Clean burner top, inspect for plugged ports, corrosion or deterioration.
Replace burner if necessary.
Inspect for flame problems.
Verify air shutter is clear of dust and debris and is in correct position
for the gas type being used.
Inspect orifice for soot, dirt, or corrosion.
Verify manifold and inlet pressures. Adjust regulator as required.
The gas hose with regulator supplied with appliance must be used for LP
installations. The replacement bust be those specified by the appliance manufacturer.
1.
6.
5.
4.
3.
2.
1.
4.
3.
2.
1.
CAUTION
Before Storing
1. Turn LP gas tank valve to “CLOSED”.
2. Turn control knob to the “ OFF” position. Note: A “poof” sound is normal as the last of the gas is burned.
3. Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.
4. Clean all surfaces.
NEVER place cover on hot outdoor fireplace.
5. Lightly coat the burner with cooking oil to prevent excess rusting.
6. If storing the outdoor fireplace indoors, cover the outdoor fireplace and store in a cool dry location away from
children and pets.
7. If storing the outdoor fireplace outdoors, cover the outdoor fireplace with the included cover for protection
from the weather.
MLOFPT108