![Royal garden FWA19930 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/royal-garden/fwa19930/fwa19930_assembly-instructions-manual_1494617017.webp)
Safety Instructions
Note:
•
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY.
•
Illustrations / diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
Checking for leaks
1. Make 2-3oz of leak detection solution by mixing one
part liquid dishwashing soap with three parts water.
2. Make sure control knobs are in the “o” position
(Figure 1).
3. Connect LP gas tank ;
4. Turn LP gas tank valve to “open”;
5. Spoon several drops of solution or use a squirt bottle,
at all “X” locations;
a. If any bubbles appear, turn LP gas tank valve to
“CLOSED”, reconnect and re-rest;
b. If you continue to see bubbles after several attempts
turn LP gas tank valve to “CLOSED” and disconnect LP
gas tank, per “Disconnecting LP Gas Tank Contact
888-690-9800 for assistance.
c. If no bubbles appear after one minute, turn LP gas tank
valve to “CLOSED”, wipe away solution proceed.
13. After lighting, observe the burner flame make sure all
ports are lit and flame height matches illustration
(Figure 3).
TURNING OFF
1. Turn LP gas tank valve to “ CLOSED”.
2. Turn control knob to the “ OFF” position. Note: A
“poof” sound is normal as the last of the LP gas is burned.
3. Disconnect LP gas tank per “Disconnecting LP Gas
Tank” section.
WARNING
Fire Risk
Provide adequate clearance
• Around air openings.
• For service access.
Locate appliance away from traffic areas.
CAUTION:After lighting-using a fire place tool
and heat-resistant gloves,carefully move the glass
beads back to their proper position,being careful to
avoid the flame.
LIGHTING
1. Make sure all labels, packaging and protective
films have been removed from flow of the outdoor
fireplace.
2. Remove cover and lid from outdoor fireplace before
lighting.
3. Check for obstructions of airflow to the burner.
Spiders, insects and webs can clog the burner/venturi
tube. A clogged burner tube can lead to a fire.
4. Control knob must be in the “ OFF” position
(Figure 3)
5. Clear small area of glass rocks away from the
igniter cover (Figure 4).
6. Connect LP gas tank per “Installing LP Gas Tank”
section.
7. Turn LP gas tank valve to “OPEN”.
8. Push and hold the electronic igniter to create sparks
within the electrode, continue to hold.
9. Push in the control knob and turn to the “ON”
position, Keep holding down the control knob to allow
gas to flow for 20 seconds.
10. After 20 seconds, release and turn control knob
counterclockwise to adjust flame to desired height.
11. If ignition does not occur in 20 seconds turn burner
control knob to “ OFF”
wait 5 minutes, fan with a newspaper or magazine, and
repeat lighting
procedure.
12. If igniter does not light burner :
a. Wearing heat-resistant gloves, position a long lit match
or long lit butane
lighter near the pilot housing.
b. Push and turn control knob to on
c. Remove match/lighter once burner is lit.
Figure 1. Clearance to Combustibles.
61
48
36
Figure 1
Figure 2
Figure 3
15.7 in-26.7in
40-68cm
MLOFPT108