background image

18” Inset Taper 010710 

Relight the appliance and allow to run for five minutes with 
the gas control in the `HIGH’ position. Check for 
satisfactory clearance of combustion products by inserting 
a lighted smoke match into the opening 

100mm

 below the 

top of the opening and 10mm in from the face of the 
surround (Fig. 21). 
 
The majority of smoke must be drawn up into the flue. If 
this does not occur, allow a further 10 minutes and repeat 
the test. Should spillage still occur, examine the chimney 
for fault and rectify. 
 
The test should be repeated if an extractor fan or fan 
powered flue appliance is fitted to the room. If there is a 
connected room with an extractor fan, the test should be 
repeated with all the connecting doors to that room 
opened. 

 

2.6 

CLEARANCE OFCOMBUSTION PRODUCTS 

 

 

 

 

 

                             18” Inset 

 

 

Fig. 21

 

 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

2.7 

FRONT AND FRETS (REQUIREMENTS FOR VENTILATION) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2.8 

ADVISING THE CUSTOMER 

 
 
Advise the customer on the following points: 
 
The lighting and extinguishing procedures that are described in section 1.3. 
 
They should read the `Instructions for Use’ section at the beginning of this booklet. 
 
The appliance should be serviced at regular intervals and checked for spillage in accordance with the method described in section 2.6. 
 
The curing effect of heating the coals will cause an initial odour. This is not harmful although additional ventilation (i.e. an opened window) 
may be required until the odour has disappeared. 
 
If the appliance is turned off or shuts off automatically, wait for at least three minutes before attempting to relight. 
 
 
 
 
 

Page 12 

Smoke match 
to be positioned 
100mm down 
and 10mm in 
from this point

Smoke match 

Minimum ventilated area of fret must be 50cm

2

 

Minimum ventilated area of front must be 60cm

2

 

Fig. 22 

The front and fret illustrated (Fig. 22), is a recommended 
CROSSLEE front and fret. If an alternative front and fret 
is to be used on the appliance, it is very important to 
maintain the equivalent ventilation. 

Содержание 18" Inset Raised

Страница 1: ...or use on NATURAL GAS G20 ONLY at a supply pressure of 20mbar Please hand this booklet to the user and advise to keep in a safe place Important Notice Before disposal of the outer packaging please enter the product code purchase and installation details in section 1 1 of this booklet 0102 095 52541 ...

Страница 2: ...ection 2 0 Installation Instructions 2 1 Important notes 2 2 Statutory requirements 2 3 Technical data 2 4 Installing the appliance Ventilation 2 4 1 Flue 2 4 2 Clearance to sides and shelves 2 4 3 Hearth Clearances 2 4 4 Fitting the appliance in position 2 4 4 1 Connecting the gas supply 2 4 4 2 Checking the appliance setting pressure 2 4 4 3 Checking the correct operation 2 5 Laying the coal peb...

Страница 3: ...ation Details Date of installation ______ ______ ______ Installed by _____________________ Registration number _____________________ Telephone number _____________________ Appliance Details Serial number _____________________ located on rating label Product Code _____________________ located on white label on outer carton It is advisable to have all the above information available if assistance is...

Страница 4: ...m impinging the hearth area Combustible materials must not be put on or left in the hearth area nor should the coal bed be used to burn rubbish or other materials This appliance uses fuel effect components gaskets and insulation material containing Refractory Ceramic Fibre RCF which are man made vitreous silicate fibres Excessive exposure to such material may cause temporary irritation to the eyes...

Страница 5: ...ation purposes only Side View Place 6 large coals pebbles on top of the simulated front one in each groove Allow the coals pebbles to rest on the support shelf Place 5 large coals pebbles on the on the first tier of the support shelf Fig 5 Place 6 small coals pebbles between the 6 large coals pebbles located on top of the simulated front Allow the coals pebbles to rest on the 5 large coals pebbles...

Страница 6: ...d supplied in the IFU kit Any part of this appliance is guaranteed against the manufacturer s defective workmanship or faulty materials for a period of twelve months from the date of purchase Any such part will be replaced free of charge on receipt of the purchaser s address at the cost of postage only Please take time to fill in section 1 1 of this booklet for your future reference Page 5 ...

Страница 7: ...are when handling these articles to ensure that the release of dust is kept to a minimum This appliance is fitted with an ODS a spillage monitoring system which operates if the evacuation of products is interrupted i e blocked or incorrect flueing If the appliance repeatedly goes out it may indicate a problem and the installer or specialist should be consulted before further use The minimum temper...

Страница 8: ...nimal cross sectional area of 100cm 2 is required Page 7 Minimum height of opening is 555mm Minimum width of opening is 415mm Injector 044 341 196 087M Gas Control MP 21301B Main Burner Aeromatix AC03 211658 Thermocouple T100 927 400 Ignition Single spark electrode direct to main burner Gas Connection 8mm OD restrictor elbow Gas Type G20 NATURAL GAS Maximum Heat Input 7 8kW 26 003btu hr Gross SPEC...

Страница 9: ...reased depth of shelf Fig 10 A SHELF CHART Fig 11 is provided to aid in calculating clearances to shelves Page 8 540mm 415 445mm 560 590mm Hatched area must be non combustible Class 1 A conventional brick or stone chimney with a minimum effective cross sectional dimension of 225mm x 225mm A lined flue with a minimum diameter of 175mm having a chair brick and throat lintel conforming to the current...

Страница 10: ...itable for the fixing plugs provided Using the No 10 x 1 woodscrews provided carefully screw the appliance into position Fig 13 2 4 4 1 INSTALLING THE APPLIANCE Connecting the gas supply A restrictor elbow complete with pressure test point is fitted to the appliance to facilitate servicing The gas supply to the appliance may be from the front left hand side or as a concealed fitting from the rear ...

Страница 11: ... control anti clockwise to the required setting Replace the fret 7 To turn the appliance off depress and turn the gas control to the OFF position 8 In the event of the piezo button failing the appliance may be lit by placing a lighted taper or match at the main burner while depressing the gas control in the IGN position IMPORTANT After turning off or if the appliance goes out for any reason wait t...

Страница 12: ...ation purposes only Side View Place 6 large coals pebbles on top of the simulated front one in each groove Allow the coals pebbles to rest on the support shelf Place 5 large coals pebbles on the on the first tier of the support shelf Fig 5 Place 6 small coals pebbles between the 6 large coals pebbles located on top of the simulated front Allow the coals pebbles to rest on the 5 large coals pebbles...

Страница 13: ...THE CUSTOMER Advise the customer on the following points The lighting and extinguishing procedures that are described in section 1 3 They should read the Instructions for Use section at the beginning of this booklet The appliance should be serviced at regular intervals and checked for spillage in accordance with the method described in section 2 6 The curing effect of heating the coals will cause ...

Страница 14: ...ling these articles although CROSSLEE recommend you follow the normal hygiene rules of not smoking eating or drinking in the work area and to always wash your hands before doing so 3 2 SERVICING COMPONENTS BELOW THE BURNER To gain access to the components below the burner remove the fibre components and the burner unit from the firebox CLEANING OR REPLACING THE INJECTOR Fig 23 Unscrew the compress...

Страница 15: ...lbow c w Pressure Test Point 0102 078 00041 1 11 Bundy Pipe Aero Burner 0102 078 04331 1 12 Heat Shield Raised Assy 0102 075 32541 1 13 Stainless Steel Baffle 0102 075 33201 1 14 Thermocouple c w Nut manuf No T100 927 400 0102 078 02351 1 15 Electrode 0102 078 02421 1 16 Rear Support Frame 0102 089 55781 1 17 Front Retaining Bracket 0102 075 33451 2 18 Baffle Spacer Plate 0102 070 31551 1 Black Co...

Страница 16: ... or technical information please contact us at Crosslee PLC Halifax West Yorkshire HX3 8DE Telephone Fax Customer Service 01422 203963 01422 204767 Service Engineer REPAIRCARE 0844 8797422 Calls cost 5p per minute from a UK BT landline Charges from mobile and other network providers may vary Page 15 ...