c)
Replace the solenoid.
d)
Check the Hall sensor.
The compressor
does not start.
a)
No water in the
system.
b)
Full ice container.
c)
The compressor stops
(overheating of the
outside of the
compressor).
a)
Check the water
connection (supply hose
and water inlet valve).
b)
Empty the ice from the
container.
c)
Turn off the unit and
after approx. 1 hour
turn it off again.
The "WATER
LOW" indicator
is on.
a)
No water in the inlet.
b)
Water valve defective.
c)
Water pressure in the
water connection is
too low.
a)
Check the running
water connection and
restart the unit.
b)
Check the water valve.
c)
Check the pressure in
the water connection.
The "FAULT"
light flashes
every second.
a)
Temperature sensor
defective.
a)
Replace the
temperature sensor.
The "FAULT"
light flashes
every 5 seconds.
a)
The water mixer
sensor does not work.
a)
Check the connection to
the water mixer sensor.
The "FAULT"
light is on
continuously.
a)
Problem with the
refrigerant system.
a)
Check the cooling
system.
WIRING DIAGRAM