MODEL
BURNERS
HEAT INPUT (KW)
I3+(28~30/37)
I3B/P(50)
I2H(20)/I2E(25)
RCGL65
2
3.0× 2
3.0× 2
3.1× 2
RCGL75
2
3.0× 2
3.0× 2
3.1× 2
RCGL110
4
3.0× 4
3.0× 4
3.1× 4
Inlet pressure (mbar)
29
50
20
Injector orifice (mm)
0.9
0.78
1.3
Destination countries
BE, CH, CY, CZ,
ES, FR, GB, GR, IE,
IT, PT, SI
AT, CH, DE,
FR, SK
AT, CH, CZ, DE,
DK, EE, ES, FI, FR,
GB, GR, IE, HU, IT,
LT, LV, NL,NO, PT,
RO, SE, SI, SK
This appliance shall be installed in conformity with the current regulations and used only in a well-
ventilated location. Consult the instructions before installing and using this appliance.
VI. TECHNICAL DETAILS
Sheet 1
Fault
Cause Analysis
Solution
Failure in ignition
•
There is no gas supply
or the gas pressure
does not fit.
•
The switch of the
appliance is damaged.
•
The ignition electrode
has loosened and
shifted.
•
Check the air inlet
and the gas pressure.
•
Replace the switch of
the appliance.
•
Adjust the position of
the ignition electrode
and make it firm.
The fire goes out
immediately after
successful ignition
•
The fire detector has
dislocated or the lead
has dropped.
•
Lack of oxygen for
combustion
•
The gas pressure is
too low or the gas
supply is insufficient.
•
Adjust the fire
detector to allow the
flame to go red.
•
Maintain good
ventilation.
•
Check and replace
the gas, or turn up
the gas supply valve.
Sheet 2
MODEL
QTY OF
BURNERS
PLATE SIZE
(WXD)
PRODUT SIZE
(WXDXH)
REMARK
RCGL65
2
600x400mm
650x580x350mm
RCGL75
3
750x400mm
800x580x350mm
RCGL110
4
1100x400mm
1150x580x350mm
14
15