FAVORITE POSITIONING

SET A FAVORITE POSITION

SEND SHADE TO FAVORITE POSITION

DELETE A FAVORITE POSITION

Move shade to the desired position by pressing the 

UP

 or 

DOWN

 button on the controller.

Press 

STOP 

on controller for 2 seconds.

Press 

STOP

 on controller.

Press 

STOP

 on controller.

Press 

P2

 on controller.

or

Motor Response

Motor Response

Motor Response

Press 

STOP

 on controller.

Press 

STOP

 on controller.

Press 

P2

 on controller.

Approx.

Motor Response

Motor Response

Motor Response

Содержание R-TEC AUTOMATION RTML25

Страница 1: ...or small commercial projects Available in three motor sizes Li ion powered motors require no electrical wiring no external battery pack and no complicated installation The Leveling Control feature all...

Страница 2: ...Motor with Controller Check Motor Direction Set Limits Adjusting Limits 9 Adjust Upper Limit Adjust Lower Limit Adding or Removing Controllers Creating Group Channels 10 Using Motor P1 Button Using a...

Страница 3: ...ATA PACK CONTENTS PRODUCT SPECIFICATIONS PACK CONTENTS Parameters Value for 25 mm Value for 28 mm Value for 35 mm Voltage 12 V DC Torque 1 1 Nm 2 0 Nm 3 0 Nm Max Run Time 10 min Speed 40 RPM Adj to 30...

Страница 4: ...and disable any equipment not needed for powered operation Ensure torque and operating time is compatible with end application Do not expose the motor to water or install in humid or damp environment...

Страница 5: ...rge management Maximum power input for recharging is 12 6V 1000mAh Before first use please charge motor for 6 hours using the recommended Battery Charger RTMLBC Option to use Solar Panel Battery Charg...

Страница 6: ...ts are set Operational control of motor run to limit Stop if running Motor runs None Operational control of motor after pairing and limit setting is completed first time If motor is in Sleep Mode limi...

Страница 7: ...MOTOR WITH CONTROLLER CHECK MOTOR DIRECTION PROGRAMMING INITIAL SET UP Motor is now in step mode and ready for setting limits IMPORTANT Consult your user manual for information on selecting channel I...

Страница 8: ...r lowest position by pressing the UP or DOWN on the controller To save upper limit hold UP and STOP To save lower limit hold DOWN and STOP or Cycle shade up and down prior to setting limits to settle...

Страница 9: ...upper limit hold UP and STOP Hold UP and STOP on the controller Move shade to the desired highest position by pressing the UP button Move shade to the desired lowest position by pressing the DOWN butt...

Страница 10: ...CONTROLLER Press P2 on existing switch Press P2 a second time on existing switch Press P2 on new switch or remote controller Motor Response Motor Response Motor Response ADDING OR REMOVING CONTROLLER...

Страница 11: ...TE A FAVORITE POSITION Move shade to the desired position by pressing the UP or DOWN button on the controller Press STOP on controller for 2 seconds Press STOP on controller Press STOP on controller P...

Страница 12: ...ER STEP MODE ENTER ROLLER MODE DEFAULT Hold UP and DOWN on the controller Hold UP and DOWN on the controller Press STOP Press STOP Approx 5 Approx 5 Motor Response Motor Response Motor Response Motor...

Страница 13: ...on controller Press UP on controller Press UP on controller Motor Response Motor Response If motor does not react to speed adjustment the maximum speed has already been reached IMPORTANT Motor Respons...

Страница 14: ...hielding Ensure transmitter is positioned away from metal objects and that antenna on motor or receiver is kept straight and away from metal Receiver distance is too far from transmitter Move transmit...

Отзывы: