30/36
Fault
Possible
cause(s)
Remedy
Tab. 4: Error diagnosis
4.5
Cleaning and maintenance by qualified persons
Maintenance work that is not listed in Chapters 4.2 - 4.4 may only be carried out by the
ROWI Service Center (see Chapter 5). In the case of maintenance work within the first 24
months that has not been carried out by persons or companies authorized by ROWI, all
warranty claims shall become null and void.
5. Warranty
5.1 Scope
ROWI grants the owner of this product a warranty of 24 months from the
date of purchase. Material or production defects shall be rectified free of charge by the
ROWI Service Center within this period.
Defects that are not due to material or production faults are excluded from the warranty,
e. g.
P
Transport damage of any kind
P
Faults due to incorrect installation
P
Faults due to improper use
P
Faults due to incorrect handling
P
Faults due to improperly performed repairs or attempts at repair by persons and/or
companies not authorized by ROWI
P
Normal wear resulting from operation
P
Cleaning of components
The appliance swit-
ches off
during operation
.
The thermal protection switch
has triggered. The appliance
has exceeded the maximum
permissible temperature.
The tip prevention switch
has triggered.
The room temperature is
above the temperature set at
the thermostat.
Switch the appliance off, by
moving the heating level switch to
position "0"
and pull the power
plug out of the socket. Allow
the appliance to cool down for
several minutes. Check the air
inlet and air outlet openings
and remedy the cause of the over-
heating before restarting the
appliance.
Make sure that the appliance is in
a vertical position and not expo-
sed to any extreme tilting.
Increase the thermostat tempe-
rature.
Содержание HKH 1500/3/3 O