Important! As soon as your vacuum cleaner starts to malfunction, and before performing any checks:
• Stop the appliance by pressing the Start/Stop switch 

• Unplug the appliance.

AMBIA will not start.

• The product is not connected to the mains  . . . . . . . . . 

Check that the product is correctly plugged in.
Check the fuse and your mains supply circuit breaker.

AMBIA does not suck.      

• Either a tool or the hose is blocked  . . . . . . . . . . . . . . . 

Unblock the tool or the hose.

AMBIA sucks less effectively, makes more noise than usual, and whistles.

• A tool or the hose is partially blocked  . . . . . . . . . . . . . 

Unblock the tool or the hose.

• The bag is full or blocked by fine dust . . . . . . . . . . . . . 

Replace the bag or empty the cloth bag.

• The foam filters and microactive filter are full  . . . . . . . 

Clean the foam filters and replace the microactive filter.

• The HEPA filter is full . . . . . . . . . . . . . . . . . . . . . . . . . . 

Change the HEPA filter.

• The cover is not properly closed  . . . . . . . . . . . . . . . . . 

Check the position of the bag on its support.

Check the position of the bag support.   

• The air regulator is open . . . . . . . . . . . . . . . . . . . . . . . 

Close the air regulator. 

• The electronic power selector is in the min. position. . . 

Increase power using the electronic power selector (except when
vacuuming delicate fabrics).

The dust bag full indicator stays red.

• The bag is full  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Replace the bag or empty the cloth bag.

• The nozzle is difficult to remove  . . . . . . . . . . . . . . . . . 

Open the suction control or reduce its power.     

AMBIA stops while vacuuming.

• The thermal cut-off switch has activated . . . . . . . . . 

Clean the motor filter, change the micro-active filter (according to model*)
and replace the bag. Allow the AMBIA to cool down for 30 minutes before
switching on again.

The power cord does not fully retract.

• The cord slows down as it is retracted . . . . . . . . . . . . . 

Pull out the cord until completely extended and press on the retraction
button 

.

The dust bag compartment cover will not close.

• The dust bag compartment cover has been 

knocked out of place.  . . . . . . . . . . . . . . . . . . . . . . . . .

Put it back in place by putting the flaps back in their holds.

Your vacuum cleaner no longer diffuses scent.

• There is no more perfume in the ceramic  . . . . . . . . . . .

Put a few more drops of perfume on the ceramic.

You are pourring some perfume on the ceramic.

• Drops of perfume fall on the product  . . . . . . . . . . . . . .

Wipe immediatly the vaccuum cleaner with a moist cloth

.

If the problem persists take the AMBIA to your nearest Rowenta Approved Service Centre.

Helpline : 0845 602 1454 (UK calls charged at local rate) (01) 47 51947 (IRELAND).