54
5.10.3.2 Quality
Figure 5.24: Quality settings
Here, you can select settings affecting the quality of the scanned originals.
1.
Resolution
: Selection of the resolution to be used for the next scanning operation. The
selection has to be made
before
the scan.
In case of the available "Turbo modes", a lower scanning resolution is used in feeding
direction and afterwards interpolation is affected. A significantly higher speed is
achieved thereby. In the selected optical resolution, the original is scanned
perpendicular to the feed direction so that interpolation is effected in feed direction,
only.
2.
Brightness
: By setting the brightness, the reproduction becomes darker or brighter. In the
text box in the middle you can enter the requested value. By means of the keys on the
left and right, the value can be reduced / increased. Setting range: -127...128 (0: neutral).
3.
Expert mode
: By pressing this button, you access a submenu with numerous further
setting options (see Figure 5.25).
Figure 5.25: Expert mode – Image settings
1.
Image settings/Color settings
: If you switch to "Color settings", you access another
submenu (see Figure 5.26).
Содержание Scan 450i 24 inch KIT 40
Страница 1: ...R O T H W E B E R G m b H APP CENTER ecoPrint Scan 450i O PE RA TIN G M AN UAL RE VI SION 1 5 3...
Страница 102: ...101 output device Parameter range you want to make the changes...
Страница 130: ...129 9 Trouble Shooting This chapter describes the actions to be taken if a problem occurs when using the scanner...
Страница 141: ...140 D About this System Copyright 2003 2014 ROTH WEBER GmbH All rights reserved...