background image

ROWAN ELETTRONICA s.r.l. - Via Ugo foscolo, 20 - 36030 CALDOGNO (Vicenza)

page 17  out of  24

INSTRUCTIONS AND DIAGRAMS FOR THE REPLACEMENT OF THE CODES 290 AND 290R CARDS WITH THE
CODE 390S CARD

To correctly replace the codes 290 and 290R cards with the 390S type card, follow the circled numbers shown in the
diagrams below.  As can be seen, the cards are interchangeable even if the terminal boards are dislocated.  The terminals
R1 S1 T1 and U1 V1 W1 are common to both power terminal boards, as is the numbering of the service terminal board
up to number 11.
If terminal 11 (motor current adjustment) is connected in the replacement 390S card, it is necessary to connect the
amperometric transformer to terminals 7 – 15, open micro S8, close micro S9 and follow the instructions given on page
14 regarding connection diagram nr. 2.

In both cases, set the micros on the code 390S card as follows:
S5 – S6 – S8 – S10 – S11 – S12      Closed
S1 – S4 – S7 – S9

   Open

S2 – S3                                             See instructions

DIAGRAM SHOWING HOW TO REPLACE A CODE 290 CARD WITH A CODE 390S CARD

DIAGRAM SHOWING HOW TO REPLACE A CODE 290R CARD WITH A CODE 390S CARD

Содержание 390S.B

Страница 1: ...E HIGH SLIP MOTORS EMC CONFORMITY Motori azionamenti accessorieserviziperl automazione Via Ugo Foscolo 20 CALDOGNO VICENZA ITALIA Tel 0039 0444 905566 4 linee r a Fax 0039 0444 905593 E mail info rowa...

Страница 2: ...ards series which are no longer produced Instructions and diagrams for the replacement of codes 290 and 290R with code 390S pag 17 Instructions and diagrams for the replacement of code 240 with code 3...

Страница 3: ...ferential input Emergency contact output can be delayed from 1 sec to 15 sec because of overload absence of line and motor phase absence of tachometrical dynamo and inverted tachometric polarity if th...

Страница 4: ...al direction of the motor is selected by exchanging 2 phases of either the supply card or the motor itself as is done with standard threephase asynchronous motors to check the rotational direction wit...

Страница 5: ...e adjustment signal input 0 10VDC to the motor max current with TA connected to terminals 7 15 from PLC or Rowan interface cards input resistance 100Kohm micro S8 open S9 closed 9 12 Internal emergenc...

Страница 6: ...urn adjustment potentiometer or differential speed control input signal 10VDC Turning in a clockwise direction increases the speed P5 Minimum revs adjusts the minimum speed of the motor with a minimum...

Страница 7: ...ermits a maximum error on motor turn variation from empty to full load of 2 r m only with trimmer P8 in the standard position S6 Closed Establishes a proportional gain on the speed control in closed l...

Страница 8: ...e of an active command at terminal 5 In this case the motor can rotate when unlit indicates that the motor cannot rotate INSTRUCTIONS FOR CONNECTING ROWAN MOTORS CONNECTING THE POWER TERMINAL BOARD Ev...

Страница 9: ...be supplied on request with an electromagnetic brake This would mean a purposely built motor with a lengthened axle and brake fitted to the front part supported by a bell shaped cover that reproduces...

Страница 10: ...al one As an alternative to the thermal relay a circuit breaker sensor could be incorporated into the motor Use relays with low current contacts for the running and stop in ramp commands or to select...

Страница 11: ...mind that the two contacts must be closed to let the motor turn Connect the speed adjusting potentiometer optimal value 10K to 3 wires of terminals 3 6 7 open the S1 micro and close S12 when cursor 6...

Страница 12: ...the set speed at departure it rotates at the maximum number of revs The L3 pilot light is lit and after approx 8 seconds pilot light L4 lights up to signal emergency intervention The card is pre set...

Страница 13: ...e card is supplied and deactivates together with the lighting up of pilot L4 in case of irregularities due to overload lack of linear and motor phase absence of tachometrical dynamo and inverted tacho...

Страница 14: ...tlet 1 2 maximum output 25A Outlet 1 3 maximum output 50A Outlet 1 4 maximum output 100A Note the tachometric rectifier should be excluded S4 closed S5 open The maximum capacity of the various outlets...

Страница 15: ...ROWAN ELETTRONICA s r l Via Ugo foscolo 20 36030 CALDOGNO Vicenza page 15 out of 24 CODE 390S CONNECTION WITH DOUBLE SPEED MOTOR Connection diagram nr 4 DRIVE SETTING FOR 2 POLE MOTOR S3 OPEN...

Страница 16: ...N FOR CONVEYOR LINES WITH CONNECTION OF TWO OR MORE MOTORS IN PARALLEL In the case of several motors the part inside the dotted line should be increased for each additional unit and the power of the C...

Страница 17: ...are common to both power terminal boards as is the numbering of the service terminal board up to number 11 If terminal 11 motor current adjustment is connected in the replacement 390S card it is neces...

Страница 18: ...by the circled numbers in the diagram below Follow the same indication for the power connections The supply line W1 V1 U1 code 240 is moved to terminals R1 S1 T1 of the code 390 and the motor outputs...

Страница 19: ...d be moved to terminal 4 of the code 390S the positive of the code 140 couple adjustment terminal should be moved to terminal 8 of the code 390S in this case micro S9 should be closed on the 390S card...

Страница 20: ...ROWAN ELETTRONICA s r l Via Ugo foscolo 20 36030 CALDOGNO Vicenza page 20 out of 24 BLOCK DIAGRAM 9 9 9...

Страница 21: ...ROWAN ELETTRONICA s r l Via Ugo foscolo 20 36030 CALDOGNO Vicenza page 21 out of 24 CIRCUIT SILK SCREENING...

Страница 22: ...the air gap is correctly regulated The inspection brake operations must be carried out with the brake electrically disconnected after checking the ground connection A good brake operation can be guara...

Страница 23: ...ELERAZIONE ACCELERATION ALIMENTATORE STABILIZZATO STABILIZED POWER SUPPLY ALIMENTAZIONE STRUMENTI E VENTILATORI MOTORI ALIMENTACI N INSTRUMENTOS Y VENTILADORES AMPEROMETRICA DI SICUREZZA AMPERIOM TRIC...

Страница 24: ...R REGOLAZIONE COPPIA COUPLE REGULATION REGOLAZIONE GIRI SPEED REGULATION RELE ESTERNO EXTERNAL RELAY RESET FUNZIONI SCHEDA RESET CARD FUNCTIONS RIPRISTINO RESET SCHEDA PREDISPOSTA PER 2 POLI S3 APERTO...