background image

MAINTENANCE

•  Clean the unit thoroughly before use and every 360 

hours to maintain proper function and cleanliness.

•  Unplug the unit before cleaning.
•  To clean the unit before use:

1.  Remove the ice scoop. Soak a soft cloth with en-

vironmental protection deterent diluted with warm 

water. Wipe the machine and accessories with the 

detergent-soaked cloth.

2.  Rinse the ice scoop with room temperature drink-

ing water. Connect the drain on the back of the 

unit to drain any residual fluid. 

3.  Wipe the outside of the unit a soft cloth and envi-

ronmental protection detergent diluted with room 

temperature water.

4.  Dry the inside and outside of the unit with a dry 

soft cloth.

•  If the unit has not been used for more 96 hours, close 

the water supply and drain residual fluid from the wa-

ter basin to maintain cleanliness. Wipe with a soft 

cloth before restarting use.

SPECIFICATIONS

MODEL

CIM-480F

CIM-720F

CIM-960F

RATED VOLTAGE

115V

115V

115V

RATED FREQUENCY

60Hz

60Hz

60Hz

RATED CURRENT

2.149A

3.012A

4.380A

REFRIGERANT

R290 / 

1.69oz

R290 / 

2.29oz

R290 / 

3.1oz

HIGH SIDE PRESSURE

275psig

275psig

275psig

LOW SIDE PRESSURE

130psig

130psig

130psig

INSULATION 

BLOWING GAS

C

5

H

10

C

5

H

10

C

5

H

10

10

11

Содержание CIM-480F

Страница 1: ...RovaEarth USER MANUAL COMMERCIAL ICE MAKER Models CIM 480F CIM 720F CIM 960F...

Страница 2: ...TABLE OF CONTENTS BEFORE STARTING PART NUMBERS INSTALLATION HOW TO USE TROUBLESHOOTING MAINTENANCE SPECIFICATIONS WARRANTY 2 3 4 6 8 10 11 12 1...

Страница 3: ...utdoors Keep away from direct sunlight Keep the unit on a level surface Do not place the unit on carpet or other fabric materials Do not cover pow er cord or keep near exposed liquid Do not use any li...

Страница 4: ...ait 24 hours before plugging in the unit WATER LINE INSTALLATION 1 Tilt the unit slightly to install the four feet 2 Mount the water filter holder 3 Connect the water line inlet pipe to the water sour...

Страница 5: ...e number of hours that the unit will remain on up to 24 hours Once a start stop timer has been set the indicator light will turn green TURNING THE LIGHT ON OFF Press the light button to turn on the in...

Страница 6: ...is air blowing from the back of the unit If there is no air check the circuit connection If the fan still does not work the part may need replacement Water pump not working Press the clean button to...

Страница 7: ...outside of the unit a soft cloth and envi ronmental protection detergent diluted with room temperature water 4 Dry the inside and outside of the unit with a dry soft cloth If the unit has not been us...

Страница 8: ...to ship the item back to the man ufacturer s facility To request a return contact the manufacturer via Amazon and provide a reason for the request This product has a limited warranty in which manu fac...

Страница 9: ......

Отзывы: