8
P/N 1011189 Rev. B 07/14
7.
Re-engage the Upper Belt Frame
Lock by lifting up and then locking
it in place on the Front Conveyor
Assembly.
8.
Close and latch the Side Panel.
NOTE:
Inform the Store Manager after
any Belt Replacement so new
Belts can be ordered. To obtain
new Belts, contact the factory at
1-877-392-7854 (North America
only) or 630-784-1000.
9.
Set the Compression Knob to 4.
10.
Re-install the Front and Rear
Conveyor Covers and then the Bun
Feeder Assembly.
11.
Reinstall the Bun Ramp (Figure 2).
12.
Plug in the toaster and test the unit
before returning to service.
CLEANING THE TOP
COOLING FAN AND ELEC-
TRICAL HOUSING (ANNU-
ALLY)
Follow these steps to clean the top fan.
1.
Turn the power switch to the OFF
position. The toaster enters a cool-
down mode and will automatically
shut down when complete.
2.
Unplug the power cord.
3.
Facing the front of the toaster,
move to the right Side Panel.
Remove the right Side Panel and set
aside. Do not lose the screws.
4.
Remove the Fan Duct cover from
the top of the unit and set aside. Do
not lose the screws.
5.
Use a plastic brush or similar tool to
brush all 5 fan blades from above
and below. Be sure to remove all
debris.
6.
Carefully clean any debris from the
inside floor of the control compart-
ment and from all electrical connec-
tions. Be sure to remove any grease,
lint, or debris from these areas.
7.
Reattach the right Side Panel
and Fan Duct cover securely with
screws.
Spacer (2)
Screw (2)
Bun Ramp (1)
Power Cord
(Rear of Unit)
Figure 2. Bun Ramp