Manual Mode
FOR EXPERT OPERATORS ONLY!
Manual Mode infers that the fusion voltage and time are obtained
directly from the operator at the time of the fusion.
Manual Mode should only be used when the
barcode is malfunctioning or unavailable
.
The temperature compensation must be calculated and
entered manually, making it difficult to ensure the proper implementation of time/temperature
compensation for fittings requiring this feature.
Since compensation factors vary for different fitting
types and manufacturers, the fitting manufacturer should always be consulted to verify proper
fusion time, voltage, and cooling time.
FAILURE TO VERIFY THAT THE FUSION INFORMATION IS CORRECT BEFORE STARTING A FUSION COULD
RESULT IN SIGNIFICANT DAMAGE TO PROPERTY, PERSONAL INJURY, AND/OR DEATH.
Power Up
Make sure the unit’s
Power button
is in the OFF position.
Make sure the generator is running smoothly in high speed manual mode before plugging in the
Roughneck
Electrofusion Processor
. It is strongly recommended that the
Roughneck Electrofusion Processor
is the only
device being powered by that generator. Do not use an extension cord if it is at all possible. If an extension
cord must be used, see page 42 for guidelines on selecting an appropriately sized cord.
Plug the 30 amp twist-lock into the appropriately sized receptacle on the generator.
NOTE:
Using a receptacle with a rating of less than 30 amps may cause generator breakers to trip while fusing
larger couplings.
Press the
Power button
to turn the processor ON.
After the processor has turned ON, start-up screens similar to the following will be displayed one after
another:
INTERNAL SELF TEST
Please wait...
INTERNAL SELF TEST
JACKMAN ROUGHNECK
CAL DUE
–
05/11/2021
PASSED
After the INTERNAL SELF TEST, if the feature is enabled, the TRACEABILITY screen will be displayed, allowing
you to enter Operator Traceability Data
. If this screen appears, see page 34 for instructions on how to enter the
data.
Содержание Jackman Fusion Equipment
Страница 1: ......
Страница 2: ......
Страница 49: ...JACKMAN FUSION EQUIP ELECTROFUSION PROCESSOR OPERATORS MANUAL REV 0 Page 47 of 48 Page Intentionally Left Blank...
Страница 50: ...JACKMAN FUSION EQUIP ELECTROFUSION PROCESSOR OPERATORS MANUAL REV 0 Page 48 of 48 Page Intentionally Left Blank...
Страница 51: ......
Страница 52: ...JACKMAN FUSION EQUIPMENT 715 S 59th Ave W Duluth MN 55807 USA www jackmanfusion com 218 302 4770...