Page 7 of 16
Installation Instructions
•
The meter can be installed in any position, with flexible and rigid piping, as well as directly on
pumps and tanks.
•
Once installed, the meter is ready for use. Press the reset button until the batch total returns to
zero. The totalizer cannot be reset any other way.
Rotating the Display (refer to parts diagram)
1. Remove the rubber shroud (1). Unscrew the four screws (2) with a Phillips head screwdriver in a
diagonal sequence and separate the electronic module (3) from the meter body (5).
2. Rotate the electronic module (3) in any of the four positions shown below and tighten the
electronic module with four screws (2).
Before Each Use
Resetting the Batch Total
1. During normal operation, the LCD display appears with a six-digit resettable total.
2. Press the MODE button to toggle between the BATCH or TOTAL display.
Subassembly
Electronic Display
Protective Shroud
Meter Body