Main Menu

Menu Items

Submenu

Items

Selections or

Information

Notes

Aw Settings

Enable AW

ON / OFF

Enable = ON changes the

display as follows:

o

Humidity unit changes

to a

w

o

No calculated

parameter

SaveResult

ON / OFF

ON: When the Aw

measurement is ended,

both the end result and

temperature are saved in

the following data bins:

Probe 1: to Bin 1

Probe 2: to Bin 2, etc.

Mode

AwQuick / AwE

o

AwQuick: accelerated

water activity

measurement

o

AwE: conventional

water activity

measurement

Dwell Time

minutes

Dwell time (AwQuick)

AwQ Temp

°C / minute

Temperature stability

definition (AwQuick)

AwE Temp

°C / minute

Temperature stability

definition (AwE)

AwE Humi

a

w

/ minute

Humidity stability definition

(AwE)

Data Storage

o

Displays the names of

the 4 data bins

Bin 1 = Probe 1

Bin 2 = Probe 2, etc.

o

Press on ENTER to

select the highlighted

data bin

View Samples

o

Shows the individual

data records

o

Use the UP and

DOWN keys to

navigate the records

Summary

Shows the minimum,

maximum and average

values for the data bin

Clear Data

Clears the data bin

QAQC LAB 589 Rappahannock Drive White Stone Va 22578 TEL (804) 318-3686

Содержание HygroLab C1

Страница 1: ...code Unit HygroLab C1 bench top indicator User Guide Instruction Manual Document Type Page 1 of 28 Document title 2011 Rotronic AG E M HyLabC1 V1_10 HygroLab C1 Bench Top Indicator User Guide QAQC LA...

Страница 2: ...vice for measuring humidity 12 4 Aw Measurement 12 4 1 Enabling Aw Measurement 12 4 2 Water activity measurement settings 13 4 3 Aw probe usage guidelines 13 4 4 Using the AwQuick mode 14 4 5 Using th...

Страница 3: ...s in typically 5 minutes The measurement starts simultaneously for all four probe inputs and is ended automatically Conventional water activity measurement AwE the measurement starts simultaneously fo...

Страница 4: ...probe inputs designed for use with all HygroClip 2 digital probes with the standard UART interface see also Back panel and digital interface options Pin Out Diagram 2 4 Measured parameters The HygroCl...

Страница 5: ...o Out of limits value defined with the HW4 software for each probe input includes measured values and calculated parameter o Display of fixed values when no probe is connected the input Easily identi...

Страница 6: ...alue When the display is set to display humidity and temperature and provided that the Aw mode is not enabled the bottom of the display shows the date and time The probe input that is currently select...

Страница 7: ...FF key ON OFF Turns the instrument on or off MENU Activates the internal menu Press this key again to go back to the previous sub menu or to exit the menu UP DOWN o Selects the probe being displayed o...

Страница 8: ...uired for calculating some psychrometric parameters Unit Sys Metric English Ref Probe 1 2 3 4 Reference probe input used to adjust probes connected to the other inputs Display Settings Trend ON OFF Tr...

Страница 9: ...1 Probe 2 to Bin 2 etc Mode AwQuick AwE o AwQuick accelerated water activity measurement o AwE conventional water activity measurement Dwell Time minutes Dwell time AwQuick AwQ Temp C minute Temperatu...

Страница 10: ...itional Options o Clear all cal points o Clear the last point Acquire Ref Probe Saves value measured by the reference probe as a cal point Acquire Ref Value Manual entry known reference environment Sa...

Страница 11: ...te or the time format Press the MENU key and select Time Settings Date Fmt or Time Fmt Press ENTER to activate either the Date Fmt or the Time Fmt menu item use the UP or DOWN arrow key to change the...

Страница 12: ...oving air is an excellent insulator When there is no air movement surprising differences in temperature and humidity can noted over short distances Air movement at the probe generally results in measu...

Страница 13: ...y signal is less than the specified value Recommended value 0 0001 Aw min SaveResult AwQuick AwE When the Aw measurement is ended the result is saved in the following data bins Probe 1 Bin 1 Probe 2 B...

Страница 14: ...the display The measurement is automatically ended and typically requires about 5 to 6 minutes With the default dwell time of 4 minutes the difference between the AwQuick function and the conventional...

Страница 15: ...ocument title 2011 Rotronic AG E M HyLabC1 V1_10 2 AWQ Dwell 3 AWQ Running HygroLab C1 starts projecting the end result Current humidity value Current temperature value AwQuick mode is in the dwell ph...

Страница 16: ...lasting 5 seconds when the last probe is done The acoustic signal can be stopped by pushing a key do not press the ENTER key When several probes are connected to the HygroLab C1 use the UP or DOWN key...

Страница 17: ...the measurement is automatically ended Depending both on the product being measured and on the stability of temperature measurements typically require 30 to 60 minutes 1 AWE Reset the HygroLab C1 is r...

Страница 18: ...gnal Beep every 5 seconds when the last probe is done The acoustic signal can be stopped by pushing a key do not press the ENTER key When several probes are connected to the HygroLab C1 use the UP or...

Страница 19: ...apture enabled Press the MENU key and select Data Storage See 3 4 Internal Menu for instructions o View Samples view individual data records o Summary view the maximum minimum and average values o Cle...

Страница 20: ...otection Disabled RS 485 address 0 Device name Instrument model Fixed barometric pressure value K 1013 25 hPa 29 92 In Hg or 14 70 PSI Date and time K Time zone dependent Unit system Metric or English...

Страница 21: ...tric calculation HygroLab C1 setting overrides HC2 probe setting Simulator function X X Generates fixed humidity and or temperature value When enabled the HygroLab C1 settings override the HC2 probe s...

Страница 22: ...C website for downloading Firmware files are given a name that shows both to which device the file applies and the version number of the firmware All firmware files have the extension HEX WARNING for...

Страница 23: ...t or to a humidity standard or to a saturated salt solution and wait for full equilibrium o Press MENU and select Probe Actions Press ENTER to activate the menu o Probe input selection with the menu i...

Страница 24: ...ab C1 automatically exits the menu o Temp Adjust the HygroLab C1 displays both the current temperature read by the probe to be calibrated and the value provided by the reference probe Press ENTER to a...

Страница 25: ...ature Display of RH temperature calculated parameter Probe inputs HygroLab C1 Number of probe inputs 4 Probe type HygroClip 2 digital humidity temperature probe Humidity and temperature measurement Hy...

Страница 26: ...ecimals water activity 1 or 2 decimals other parameters Display modes Water activity and temperature RH and temperature date and time RH temperature and calculated parameter Housing material ABS Alumi...

Страница 27: ...mon to all devices E M HW4v3 F2 019 HW4 software version 3 HygroLab C1 hand held indicator and probes Device Manager and Data Recording functions E M HW4v3 F2 001 HW4 software version 3 Device Manager...

Страница 28: ...b C1 bench top indicator User Guide Instruction Manual Document Type Page 28 of 28 Document title 2011 Rotronic AG E M HyLabC1 V1_10 11 Document releases Doc Release Date Notes _10 Oct 19 2011 Origina...

Отзывы: