OPERATION: 

HOW TO TROUBLESHOOT THE ER6 ERROR CODE ON CONTROLLER

ER6 appears

on touchpad

Have you recently

changed the water?

Ensure that an

adequate amount

of water is in the

spa, if not the pump

may suck in air

causing an airlock.

Re-set spa by

simultaneously

pressing: up, down,

pump buttons, ER6

should disappear.

Ensure all jet faces

are in the ‘open’

position. Turn pump

onto speed 2.

Leave running and

repeat if necessary.

Has ER6 message

disappeared?

Remove filter, inspect

and clean or replace

as necessary.

Re-set spa by

simultaneously

pressing: up, down,

pump buttons, ER6

should disappear.

If problem re-occurs,

check the water

pressure from jets;

is the pressure

uniform and strong

through all jets on

both pump speeds?

Please call your

RotoSpa Dealer for

further advice.

Congratulations!

Содержание Quip SP601

Страница 1: ...rder to obtain maximum benefit from your RotoSpa we recommend that you read and follow the information contained in this guide This guide is not intended as a complete manual on spa ownership but a ge...

Страница 2: ...TS 2 3 INSTALLATION 3 Location Setting Up Connection 4 OPERATION 4 5 Spa Quip SP601 Control System Troubleshooting 5 MAINTENANCE 6 7 Chemicals Filtration Cleaning Draining 6 SAFETY 8 7 WARRANTY LEGAL...

Страница 3: ...urface from scratching to preserve its appearance Once you have sited your spa the packaging can be removed from your spa and all of its accessories The lockable thermal cover when supplied is rigid a...

Страница 4: ...YDRO JET SYSTEM You can adjust the silent air intake control to increase or decrease the air content in the jet streams The power of most jets can be individually adjusted by a part turn of the fascia...

Страница 5: ...n pump buttons ER6 should disappear Ensure all jet faces are in the open position Turn pump onto speed 2 Leave running and repeat if necessary Has ER6 message disappeared Remove filter inspect and cle...

Страница 6: ...e a pH level of between 7 2 7 6 The efficiency of the disinfectant i e chlorine or bromine is directly related to the pH of the water Total alkalinity should be maintained in the range between 100ppm...

Страница 7: ...reduce the build up of Total Dissolved Solids including wastes such as perspiration and cosmetics To empty the spa simply use a hose by holding the end over one of the jets until water begins to flow...

Страница 8: ...lood pressure before using a spa TIME TEMPERATURE The higher the water temperature the less time should be spent in the spa Time can be gradually increased as your body becomes accustomed to the activ...

Страница 9: ...cial application Terms Conditions This is not an infield warranty unless purchased directly from RotoSpa Limited and in the event of a fault covered by the warranty the defective part shall be replace...

Отзывы: