Roto Safe Eneo C, CC and CF

1

2

3

4

5

6

Eneo C / CC / CF

GND

K1b

K1a

IN2

+24V

IN1

black

green

pink

pink

pink

bro

wn

bro

wn

brown

brown

brown

bro

wn

gre

y

gre

y

gre

y

green

green

green

green

green

yello

w

yello

w

yello

w

yellow

white

white

white

white

EZ-cable 3m

insertable
cable junction

on the sash

on the frame

Switch

power supply
Eneo

Switch

"Day / Night"

N

IN: 100-240V AC
OUT: 24V DC/ 2,5A

+V -V

+24VGND

L

plug / cable assignment

white:  IN1 / Input 1 (open)
brown:   +24V
green:  GND
yellow: IN2 / Input 2 (day/night)
grey:  K1a dry contact
pink:  K1b dry contact

INFO

If there is +24 V voltage at terminal 4, the lock is in “day operation mode”. If there is no voltage, the lock
is in “night operation mode”.This can be used as an option.

Terminals 5 and 6 are connected to one another internally via a relay and a 47 ohm resistor. The
maximum load of the contacts is 24 V / 40 mA.

Maximum line lengths

Eneo cable junction, insertable 180°, incl. 4 m cable with
round connector for Eneo Control Unit up to power
supply unit.

From Eneo cable junction connector

Up to 4 m

Up to 10 m

Up to 20 m

Up to 30 m

Up to 50 m

0.34 mm

2

0.75 mm

2

1 mm

2

1.5 mm

2

2.5 mm

2

Eneo cable junction 180° opening, not insertable, with
cable for cable junction 7 x 0.5 mm

2

, 10 m.

From Eneo drive unit

Up to 10 m

Up to 20 m

Up to 30 m

Up to 50 m

0.5 mm

2

1 mm

2

1.5 mm

2

2.5 mm

2

INFO

If a cable junction with built-in power supply
unit is used, it must have three poles and a
cable cross section of 1.5 mm

2

.

Roto Safe Eneo

Subject to change.

Roto Safe Eneo

SUG_11_EN_v0

 · 

04 / 2019

 · 3

 

Содержание Safe Eneo Series

Страница 1: ... out work when the power supply is disconnected Technical data Roto Safe Eneo drive Voltage 24 V DC 5 2 5 A SELV output voltage according to EN 60950 1 Continuous current consumption 25 mA Current consumption 1 5 A peak 2 3 A Relative air humidity 93 Temperature 25 to 60 C transport 25 to 70 C Output relay load Max 40 mA flyback diode for inductive load present internally Standards EN 60 730 1 EN ...

Страница 2: ...not connected not connected green green green yellow white white white white EZ cable 3m insertable cable junction on the sash on the frame power supply Eneo Switch IN 100 240V AC OUT 24V DC 2 5A plug cable assignment white IN1 Input 1 open brown 24V green GND yellow not connected grey not connected pink not connected Roto Safe Eneo 2 04 2019 SUG_11_EN_v0 Roto Safe Eneo Subject to change ...

Страница 3: ...ight operation mode This can be used as an option Terminals 5 and 6 are connected to one another internally via a relay and a 47 ohm resistor The maximum load of the contacts is 24 V 40 mA Maximum line lengths Eneo cable junction insertable 180 incl 4 m cable with round connector for Eneo Control Unit up to power supply unit From Eneo cable junction connector Up to 4 m Up to 10 m Up to 20 m Up to ...

Страница 4: ...pproximately 2 seconds Unlocking the door from the outside Depending on the access control system available unlocking can be triggered by hand held transmitter finger scan Phone Code etc INFO If the deadbolt is locked the lock cannot be opened electronically Unlocking the door from the inside The Eneo C multipoint locking system can only be unlocked using a key or electrical signal e g push button...

Страница 5: ...ing the Eneo Control Unit Contact qualified personnel Roto Safe Eneo does not lock automati cally Door is not fully closed Close the door fully Multipoint locking system is in day operation mode Change over to night operation mode input 2 must not be set to 24 V for night operation mode Rebate magnet is adjusted incorrectly Check the position of the magnet and adjust if necessary Adjust the door a...

Страница 6: ...ioned adjusted correctly Lock the door again Position the magnet correctly and lock the door again 3x two tone beeps Fault Control unit detected excess current in the motor and stopped Remove blocks If the door is not running smoothly contact the door manufacturer 4x two tone beeps Fault The final position of the connecting rod was not reached in the maximum permitted time of 3 seconds No movement...

Страница 7: ...Str 21 A 8401 Kalsdorf bei Graz Austria Notausgangsverschluss lt EN179 E611 LE DoP Nr KD Door E611 Nr 001 CPR 2016 05 17 16 EN 179 2008 04 Notausgangsverschluss mit Drückerbetätigung Typ A für Türen in Rettungswegen für außen und innen öffnende Türen n e d n a t s e b e b a g i e r F r u z t i e k g i h ä F 1sec W 100mm A 70N Dauerfunktionstüchtigkeit hinsichtlich der Fähigkeit zur Freigabe gegenü...

Отзывы: