24
LUBRICATION CHART
DISENGAGE PTO & SHUT OFF POWER BEFORE LUBRICATING THE MACHINE.
LOOSE OR FLOPPY CLOTHING SHOULD NOT BE WORN BY THE OPERATOR.
OIL BATH:
Fill the oil bath with 30 weight motor oil to sight plug level.
GREASE BANK:
Grease every 100 hours.
FRONT END BEARINGS:
Grease every 100 hours.
INPUT BEARINGS:
One (1) on input shaft beneath mixer/feeder. Grease every 100
hours.
PTO SHAFTS & U-JOINTS:
Grease every 10 to 20 hours.
GEARBOX:
Prior to operation, remove the uppermost plug and replace with vent plug
provided. After the first 100 hours of operation, drain the initial oil,
preferably warm. Flush the gear case with an approved non-flammable,
non-toxic solvent and refill with oil. Thereafter oil should be changed
every 2500 hours or every 12 months, whichever occurs first. Fill the
gearbox with 1-1/2 pints of (Mobil Delvac Synthetic Gear Oil 75W-90).