22
LUBRICATION CHART
DISENGAGE PTO & SHUT OFF POWER BEFORE LUBRICATING THE MACHINE.
LOOSE OR FLOPPY CLOTHING SHOULD NOT BE WORN BY THE OPERATOR.
PTO SHAFTS & U-JOINTS:
Grease every 10 to 20 hours.
AUGER GEARBOXS:
After the first 100 hours of operation, drain initial oil,
preferably when box is warm. Flush out the gear case with an approved non-
flammable, non toxic solvent and refill with oil. Thereafter oil should be changed
every 2000 hours or 12 months, whichever comes first. If machine usage is severe or
more than 10 loads per day, it is advisable to change the oil every 1000 hours or 6
months. Inspect and wash oil reservoir breather cap as needed. Air dry before
reinstalling. Fill each gearbox with approximately 5 1/2 gallon of
(Synthetic Gear
Lube 75W-90).
PROCEDURE FOR FILLING AUGER GEARBOX:
Remove pressure side oil line from
circulation pump and attach to oil supply pump. Pressure oil in gear box until oil
starts to show in bottom of sight gauge on oil reservoir. Reconnect oil line to
circulation pump. Fill reservoir to center of sight gauge, run unit and add oil up to
center of sight gauge if needed. Check daily, oil level must always be visible in sight
gauge.
Note: Do not fill gearbox through oil reservoir.
OIL FILTER SERVICE:
All filters should be changed the first 24 hours after start up of
the system, and there after during normal maintenance every 500 hours of service.
10 micron filter elements are recommended. All reservoirs should be checked daily
for proper fluid level. Visually check daily for any fluid leakage.
1:2 INCREASER GEARBOX:
After the first 100 hours of operation, drain initial oil,
preferably when box is warm. Flush out the gear case with an approved
nonflammable, non toxic solvent and refill with oil. Thereafter oil should be
changed every 2000 hours or 12 months, whichever comes first. Fill the gear box to
sight plug with approximately 7 pints of,
NOTE: (Synthetic Gear Lube 75W-90).
GEARBOX TEMPERATURES:
During normal running conditions, the temperature of the
outer casing of the gearbox should not exceed 175ºF (80ºC).
RECOMMENDATION:
It is advisable to check the oil level of gearboxes at least
once a month. If more than 10% of the total oil capacity has to be added, check
for oil leaks.
Содержание 1105A
Страница 2: ...2...
Страница 30: ...244 1 2 307 1 2 187 145 1505A 135 1355A 99 1 2 15 123 1355A 1505A SIDE DISCHARGE DIMENSIONS 30...