![Rothewald 10002896 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/rothewald/10002896/10002896_operating-instructions-manual_1491529002.webp)
- 2 -
Technical specifications
Display accuracy is guaranteed for a period of one year following calibration at
temperatures between 18 and 28°C and at up to 80% humidity.
Fuse:
F 200 mA / 250 V
Battery:
9V battery
Display:
3 1/2 digit, 15 mm high LCD
2-3 updates / sec.
"Measuring range exceeded" message: number "1" appears on the display
"Reversed polarity" message:
"-" appears on the display
"Low battery" message:
battery symbol appears on the display
Operating temperature:
0 to 40°C
Storage temperature:
-10 to 50°C
Max. humidity for storage:
80%, non-condensing
Dimensions:
138 x 69 x 31 mm
Weight:
approx. 160 g
Mode
Measuring range Resolution
Accuracy
DC voltage
200 Mv
0.1 mV
+/-(0.5% +/-2 dgts)
2 V
1 mV
+/-(0.5% +/-2 dgts)
20 V
10 mV
+/-(0.5% +/-2 dgts)
200 V
100 mV
+/-(0.5% +/-2 dgts)
600 V
1 V
+/-(0.8% +/-2 dgts)
AC voltage
200 V
100 mV
+/-(1.2% +/-10 dgts)
600 V
1 V
+/-(1.2% +/-10 dgts)
AC voltage frequency 40 to 400 Hz