ENGLISH
38
(
ROWELD P 250/8 B
: the total cylinder surface is 6.26 cm²)
(
ROWELD P 355/12 B
: the total cylinder surface is 6.26 cm²)
(
ROWELD P 500/18 B
and
P 630/24 B
: the total cylinder surface is 14.13 cm²)
(
ROWELD P 630/24 B Plus
the total cylinder surface is 22.38 cm²)
3.5
Setting parameters
To set the parameters with „welder“ rights:
Press the adjusting knob
(4)
for a long time (about 3 sec.) until P001 blinks in the upper
display
(2)
.
Use the adjusting knob
(4)
to select the desired parameter P001 to P009. If this value must
be adjusted or displayed, briefly press the adjusting knob
(4)
. The (default) value blinks in the
lower display
(9)
.
Use the adjusting knob
(4)
to set the value, and press the adjusting knob
(4)
briefly again.
Then the parameter blinks again in the upper display
(2)
.
To leave the menu, press the release button
(10)
. The values are stored.
How to set parameters with „master“ rights:
Press the adjusting knob
(4)
for an extended time (about 6 sec.). First the parameter P001
blinks in the upper display
(2)
. Then „CodE“, and the line blinks in the first place in the lower
display
(9)
.
Then use the adjusting knob
(4)
to enter the code, and briefly press the adjusting knob
(4)
(code = 8001 – during first use the code can be changed as desired through parameter P100).
Use the adjusting knob
(4)
to select the desired parameter, P101 to P114. If this value must
be adjusted or displayed, briefly press the adjusting knob
(4)
. The (default) value blinks in the
lower display
(9)
.
Use the adjusting knob
(4)
to set the value, and press the adjusting knob
(4)
briefly again.
Then the parameter blinks again in the upper display
(2)
.
To leave the menu, press the release button
(10)
. The values are stored.
Parameter
name
Description
default Unit
min
max
Rights
P001
Remaining energy saver time
99
min
0
99
Welder
P002*
Power saving function active
0
0
3
Welder
P003
Heating plate temperature offset 5
°C
-25
25
Welder
P004
Pmax for cutting
20
bar
10
50
Welder
P005
Target pressure
1/10 bar
Welder
P006
Target temperature
210
°C
P103 P104
Welder
P007
Timer T1 target value
45
sec
1
1500 Welder
P008
Timer T4 target value
6
min
1
99
Welder
P009
Pstart for cutting
10
bar
0
P004
Welder
P101
Deviation for repumping
5
%
1
50
Master
P102
Lifting time after cutting
10
1/10 sec 0
100
Master
P103
Set temperature (min)
160
°C
0
300
Master
P104
Set temperature (max)
270
°C
0
300
Master
P105
Button lock (yes/no)
5
sed
0
50
Master
P106
Lifting pressure
135
bar
10
160
Master
P107
Full runtime until buzzer goes on 50
1/10 sec 0
200
Master
P100
Change code
8001
Master
* P002 - Power saving function:
0 - none,
1 - when the miller is running the heating element will be switched off,
2 - when the hydraulic motor is running the heating element will be switched off,
3 - when t4 is running the heating element will be switched off.