Installation manual
4
R260AB
Domestic hot water tank for air to water heat pump system
4PW61220-1
2 Installation position.
The 3-way valve must be installed in the indoor unit.
3 Unpack the 3-way valve body and 3-way valve motor.
Verify that following accessories are provided with the motor.
4 Put the sleeve on the valve and turn the valve so that the
sleeve is positioned according to the figure below.
5 Install the 3-way valve body in the piping.
Refer to the figure below before making the connection.
6 Push the motor on the sleeve.
Make sure not to rotate the sleeve during this action, so as to
maintain the valve position as set during step 4.
7 Put the turn knob on the valve motor cover as shown below.
Make sure that the turn knob is completely pushed in to allow
the turn knob being operated automatically by the unit. If the
turn knob is lifted slightly, manual operation is possible.
1
Sleeve
2
Valve motor cover
3
Screw
4
Turn knob
If the valve is not positioned in this way before
mounting the motor, the valve will give way to both
domestic water and room heating during operation.
1
3
2
1
From indoor unit
2
To domestic hot water tank
3
To room heating
1
2
3
4
45
45
°
45
°
45
°
45
45
°
45
°
Room heating
Domestic hot water tank
A
B
C
4
1
2
2
3
5
6
7
9
8
10
11
11
13
14
15
16
12
1D_IM_4PW61220-1.book Page 4 Monday, April 19, 2010 3:41 PM