3 Operation

Operation manual

7

R2CND0 R2TND012~024A4AA
Wall-mounted condensing boiler
3P469438-4D – 2017.07

3.3.8

About the domestic hot water comfort
mode

The domestic hot water comfort mode includes a domestic hot water
pre-heat function and a domestic hot water post-heat function. When
the comfort mode is enabled, both pre-heat and post-heat functions
are enabled.

The pre-heat function is a self-learning algorithm according to which
the  boiler  will  heat  up  the  domestic  hot  water,  before  the  tapping
demand. The algorithm is based on your personal use pattern of the
last 24 hours.

Note: 

Independent  of  personal  use  pattern,  comfort  mode

preheating  function  could  be  adjusted  to  operate  continuously  from
the user settings.

The  post-heat  function  heats  up  the  domestic  hot  water  heat
exchanger  after  tapping,  when  the  flow  temperature  of  the  boiler  is
below the domestic hot water temperature setpoint.

Comfort  mode  can  be  enabled  from  the  user  settings  menu  (see

"User settings menu: Parameters (short)" on page 8

).

INFORMATION

Domestic  hot  water  comfort  mode  is  only  valid  for
instantaneous type hot water supply types.

When the domestic hot water comfort mode is enabled, the   icon is
shown on the screen.

The   icon blinks when the burner is on for comfort mode.

3.3.9

About the boiler frost protection

Frost protection safety system:

 This function protects the unit and

heating installation from frost damages. This protection activates the
boiler  pump  when  the  water  temperature  drops  below  13°C  and  it
activates  the  burner  when  the  water  temperature  drops  below  8°C
(factory  setting).  The  unit  keeps  running  until  the  temperature
reaches 30°C. To enable this function, the unit must be connected to
the power supply and its main gas valve must be open. Any damage
caused  by  frost  is  not  covered  by  the  warranty.  Frost  Protection  is
enabled in all modes, including standby mode and full-off mode.

WARNING

If  the  boiler  is  not  connected  to  the  power  supply,  frost
protection  is  not  active.  Consequently,  the  water  may
freeze  and  cause  cracks.  The  manufacturer  is  not
responsible for any damage that may occur this way.

NOTICE

When  not  using  the  boiler,  we  strongly  recommend  not  to
cut off the electric supply to the boiler.

3.4

Error handling

When an error occurs, the normal behaviour of the user interface is
interrupted,  and  the  status  of  the  status  indicator  is  affected.
However,  be  aware  that  not  all  errors  have  the  same  effect  on  the
user interface and the status indicator.

Error

type

Boiler operation

User interface and status

indicator

Warning Continue

The status indicator does not enter
error mode if the burner is on. It
turns to red when the burner is off.
The LCD screen stays active and
displays the error code.

Blocking Blocked, turns back

to operation if
cause disappears

The status indicator enters error
mode. The LCD screen stays active
and displays the error code.

Error

type

Boiler operation

User interface and status

indicator

Lockout

Blocked and a
reset is required

The status indicator enters error
mode. The LCD screen stays active
and displays the error code. Also,
the   icon starts blinking, indicating
that a reset is required

.

In case of a warning or a blocking error, the user interface will leave
error  mode  and  return  to  the  home  screen  when  the  cause  of  the
error disappears.

In  case  of  a  lockout  error,  the  boiler  needs  to  be  reset.  Press  the
"Reset" button to remove the error, if the cause of the error is gone.
If  the  cause  of  the  error  is  still  there,  the  user  interface  will  enter
error  mode  again.  When  the  error  is  solved,  the  user  interface
returns to the home screen.

If  you  turn  any  dial  or  press  any  button  (except  the  "Reset"  button)
during an error, the user interface will display the home screen. After
the  timeout  without  any  interaction,  instead  of  darkening,  the  user
interface will enter error mode.

NOTICE

A  table  with  all  error  codes,  the  reasons  for  their
appearance,  and  possible  solutions,  is  located  at  the  very
end of this manual.

3.5

Menu functions

3.5.1

To use menu level 1

1

Press the "Menu" button while you are at home screen to go the
Menu screen. This is menu level 1 screen.

2

To switch between info, user settings and service settings, turn
the left dial.

3

To leave the menu and return to the home screen, press "Back"
for 2 seconds.

When there is no user interaction for one minute, the user interface
will leave the menu and switch to the blank screen.

3.5.2

Info menu

Info menu: Parameters

The  info  menu  ( )  covers  all  possible  information  that  is  made
available  to  the  end  user  and  to  the  installer.  This  parameters  are
read only and cannot be changed.

#

Description (short)

Unit

A00

Actual flow temperature

°C

A01

Actual return temperature

°C

Содержание R2CND-A4A

Страница 1: ...Operation manual Wall mounted condensing boiler English Operation manual Wall mounted condensing boiler R2CND024A4AA R2TND012A4AA R2TND018A4AA R2TND024A4AA ...

Страница 2: ...pply Filling loop R2CND024A4AA R2CND024 Instantaneous External R2TND012A4AA R2TND012 Storage tank External Model Type Domestic hot water supply Filling loop R2TND018A4AA R2TND018 Storage tank External R2TND024A4AA R2TND024 Storage tank External A control unit which contains a user interface controls the ignition safety systems and other actuators User interaction is provided via that user interfac...

Страница 3: ...Do not damage or remove any seals on components Only qualified persons are allowed to alter sealed components Do not make any modifications on Boiler Gas water or power supply Flue system 2 4 Gas conversion WARNING Never attempt to do gas conversion yourself Only qualified persons can do gas conversion Contact your service agent This unit is able to be operated with both natural gas and LPG The pr...

Страница 4: ...iler Status Description Standby When there is no heat demand the status indicator shows this with a kind of breathing pulsation of the blue and white LED Flame At the moment flame ignites for central heating or domestic hot water the ring flashes to its maximum then constantly keeps glowing during burner operation Error The status indicator will go into error mode when a warning lockout or blockin...

Страница 5: ...ter operation is active Operation mode Description Winter mode Both domestic hot water operation mode and central heating operation mode are enabled The boiler can produce domestic hot water as well as produce heat for central heating The central heating temperature setpoint which setpoint is shown depends on the system configuration see 3 3 5 Possible central heating operation modes on page 6 and...

Страница 6: ...ial Increasing or decreasing the setpoint value reflects to the central heating water temperature and the room temperature respectively The and icons are shown on the screen when central heating operation mode is enabled NOTICE To enable weather compensation the heating slope value must be higher than 5 see User settings menu Parameters short on page 8 INFORMATION If an outdoor sensor is connected...

Страница 7: ...ing When an error occurs the normal behaviour of the user interface is interrupted and the status of the status indicator is affected However be aware that not all errors have the same effect on the user interface and the status indicator Error type Boiler operation User interface and status indicator Warning Continue The status indicator does not enter error mode if the burner is on It turns to r...

Страница 8: ...dependency 1 1 2 or 24 U10 Room temperature setpoint used by ROTEX Opentherm room thermostat during night C 18 10 30 User settings menu Parameters detailed Description U00 When using outdoor sensor above this parameter value of outside temperature the boiler senses the season as summer and does not activate central heating although there is demand Summer winter switching has a hysteresis of 1ºC i ...

Страница 9: ...of your boiler with a damp cloth and a little solvent free soap CAUTION Sprays solvents or cleaning agents containing chlorine can damage the exterior the fittings or the control unit Do not use them for cleaning purposes 5 Energy saving tips Operating the unit in central heating ECO mode provides the most economical central heating operation conditions Do not run the boiler in domestic hot water ...

Страница 10: ...eded If problem repeats contact your service agent E1 66 Calibration conditions fault No reset needed Wait burner to restart If problem repeats contact your service agent E1 67 Missing calibration Perform reset If problem repeats contact your service agent Problem Solution E1 68 Ion base value is outside the factory limits or saved incorrectly Perform reset If problem repeats contact your service ...

Страница 11: ...Solution UA 66 BCC ID of internal EEPROM is inconsistent Contact your service agent UA 67 BCC is missing Contact your service agent UA 68 BCC is not compatible with PCB BCC ID Contact your service agent UA 69 BCC is not compatible with PCB firmware Contact your service agent UA 70 BCC update error Contact your service agent ...

Страница 12: ...land Our partners abroad Unsere Partner im Ausland Nos partenaires à l étranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granicą Naši partneři v zahraničí http de rotex heating com ueber rotex international 3P469438 4D 2017 07 ROTEX Subject to change and correction ...

Отзывы: