7 Technical data

Installation manual

11

07C2V3
ROTEX HPSU monobloc compact outdoor unit
4P501825-1 – 2017.08

7.2

Wiring diagram: Outdoor unit

See the internal wiring diagram supplied with the unit (on the inside of the outdoor unit switch box cover). The abbreviations used are listed
below.

Outdoor unit: compressor module

C110~C112

Capacitor

DB1, DB2, DB401

Rectifier bridge

DC_N1, DC_N2

Connector

DC_P1, DC_P2

Connector

DCP1, DCP2,

Connector

DCM1, DCM2

Connector

DP1, DP2

Connector

E1, E2

Connector

E1H

Drain pan heater

FU1~FU5

Fuse

HL1, HL2, HL402

Connector

HN1, HN2, HN402

Connector

IPM1

Intelligent power module

L

Live

LED 1~LED 4

Indication lamps

LED A, LED B

Pilot lamp

M1C

Compressor motor

M1F

Fan motor

MR30, MR306,
MR307, MR4

Magnetic relay

MRM10, MRM20

Magnetic relay

MR30_A, MR30_B

Connector

N

Neutral

PCB1

Printed circuit board (main)

PCB2

Printed circuit board (inverter)

PCB3

Printed circuit board (service)

Q1DI

Earth leakage circuit breaker

Q1L

Overload protector

R1T

Thermistor (discharge)

R2T

Thermistor (heat exchanger)

R3T

Thermistor (air)

S1NPH

Pressure sensor

S1PH

High pressure switch

S2~S503

Connector

SA1

Surge arrestor

SHEET METAL

Terminal strip on fixed plate

SW1, SW3

Push buttons

SW2, SW5

DIP switches

U

Connector

V

Connector

V2, V3, V401

Varistor

W

Connector

X11A, X12A

Connector

X1M, X2M

Terminal strip

Y1E

Electronic expansion valve coil

Y1R

Reversing solenoid valve coil

Z1C~Z4C

Ferrite core

Field wiring

Terminal strip

Connector

Terminal

Protective earth

BLK

Black

BLU

Blue

BRN

Brown

GRN

Green

ORG

Orange

PPL

Purple

RED

Red

WHT

White

YLW

Yellow

Outdoor unit: hydro module

English

Translation

(1) Connection diagram

(1) Connection diagram

External outdoor ambient sensor
option

External outdoor ambient sensor
option

Hydro switch box

Hydro switch box

Indoor

Indoor

NO valve

Normal open valve

Outdoor

Outdoor

Power supply

Power supply

(2) Hydro switch box layout

(2) Hydro switch box layout

(3) Notes

(3) Notes

X4M

Main terminal

Earth wiring

15

Wire number 15

Field supply

1

Several wiring possibilities

Option

Wiring depending on model

Switch box

PCB

(4) Legend

(4) Legend

A1P

Main PCB

A2P

Current loop PCB

Q*DI

#

Earth leakage circuit breaker

R6T

*

External outdoor ambient sensor
option

TR1

Power supply transformer

X*M

Terminal strip

X*Y

Connector

PCB3

Service PCB

M2S

#

Shut-off valve

XAG1

Terminal strip

*:

Optional

#:

Field supply

Содержание HPSU

Страница 1: ...Installation manual ROTEX HPSU monobloc compact outdoor unit English Installation manual ROTEX HPSU monobloc compact outdoor unit ...

Страница 2: ... souladu s našimi pokyny odpovídají následujícím normám nebo normativním dokumentům u skladu sa slijedećim standardom ima ili drugim normativnim dokumentom ima uz uvjet da se oni koriste u skladu s našim uputama 16 17 18 19 20 21 22 23 24 25 megfelelnek az alábbi szabvány ok nak vagy egyéb irányadó dokumentum ok nak ha azokat előírás szerint használják spełniają wymogi następujących norm i innych ...

Страница 3: ... 4 4 3 To connect the remote outdoor sensor 8 4 4 4 To connect the shut off valve 8 5 Commissioning 9 5 1 Checklist before commissioning 9 6 Hand over to the user 9 7 Technical data 10 7 1 Piping diagram Outdoor unit 10 7 2 Wiring diagram Outdoor unit 11 1 About the documentation 1 1 About this document Target audience Authorised installers Documentation set This document is part of a documentatio...

Страница 4: ...he user interface does NOT display error 7H NOTICE When circulation in each or certain space heating loops is controlled by remotely controlled valves it is important that the minimum flow rate is guaranteed even if all valves are closed In case the minimum flow rate cannot be reached a flow error 7H will be generated no heating or operation See the installer reference guide for more information M...

Страница 5: ...the floor prepare 4 sets of M8 or M10 anchor bolts nuts and washers field supply as follows INFORMATION The maximum height of the upper protruding part of the bolts is 15 mm 283 1 0 0 mm 1 0 0 330 300 7 4 0 In any case provide at least 300 mm of free space below the unit Additionally make sure the unit is positioned at least 100 mm above the maximum expected level of snow mm 1 5 0 1 5 0 a 330 300 ...

Страница 6: ...dboard b Instruction sheet NOTICE To prevent damage to the supporting feet do NOT tilt the unit sideways in any way 4 2 3 To provide drainage Make sure that condensate can be evacuated properly When the unit is in cooling mode condensate may also form in the hydro part When providing drainage therefore make sure to cover the entire unit NOTICE If the unit is installed in a cold climate take adequa...

Страница 7: ...the shut off valves 3 For how to connect the HPSU monobloc tank see the installation manual of the tank NOTICE To protect the water circuit against freezing add glycol For instructions see the installation manual of the HPSU monobloc tank NOTICE Install a manometer in the system NOTICE Install air purge valves at all local high points 4 3 2 To insulate the water piping The piping in the complete w...

Страница 8: ...upply 4 Make sure that the cable does NOT come in contact with sharp edges 5 Install the switch box cover INFORMATION When installing field supply or option cables foresee sufficient cable length This will make it possible to remove reposition the switch box and gain access to other components during service CAUTION Do NOT push or place redundant cable length in the unit 4 4 2 To connect the main ...

Страница 9: ...n devices are installed according to this document and have not been bypassed The power supply voltage matches the voltage on the identification label of the unit There are NO loose connections or damaged electrical components in the switch box There are NO damaged components or squeezed pipes on the inside of the outdoor unit The correct pipe size is installed and the pipes are properly insulated...

Страница 10: ...or Accumulator Compressor High pressure switch Muffler Muffler 4 way valve Pressure sensor Refrigerant flow Cooling Heating Liquid stop valveV Plate heat exchanger Gas stop valve with service port Air purge Flow sensor Pump Flow switch Outlet Shut off valve with drain fill valve Expansion vessel Safety valve Blow off Filter Inlet Outlet water heat exchanger thermistor Refrigerant liquid side therm...

Страница 11: ... S1PH High pressure switch S2 S503 Connector SA1 Surge arrestor SHEET METAL Terminal strip on fixed plate SW1 SW3 Push buttons SW2 SW5 DIP switches U Connector V Connector V2 V3 V401 Varistor W Connector X11A X12A Connector X1M X2M Terminal strip Y1E Electronic expansion valve coil Y1R Reversing solenoid valve coil Z1C Z4C Ferrite core Field wiring Terminal strip Connector Terminal Protective eart...

Страница 12: ...SU monobloc compact outdoor unit 4P501825 1 2017 08 Electrical connection diagram Hydro switch box Power Supply Q3DI X3M X5M X5M XAG1 X4M 1N 50 Hz 230 V AC Power supply L N L N M2S NO Valve 1 2 2 1 2 1 1 2 5 6 external outdoor ambient sensor option 4D112157A R6T t ...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...sland Our partners abroad Unsere Partner im Ausland Nos partenaires à l étranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granicą Naši partneři v zahraničí http de rotex heating com ueber rotex international 4P501825 1 2017 08 ROTEX Subject to change and correction ...

Отзывы: