6
x
Controller and electronic components
6 Controller and electronic components
6.1 Operating elements on the boiler control
panel
Mains switch
Switch the ROTEX GCU compact on and off. When the heating
system is on, the mains switch is illuminated green.
Control panel for the RoCon B1
The control panel is equipped with a coloured backlit clear text
display.
The colour of the backlighting indicates the operational status
and the programming mode:
In normal system operation the rotary switch should be in the
"Info"
position.
The most important system temperatures and operating states
are shown on the controller display.
The ROTEX GCU compact is fitted with the ROTEX RoCon BF controller. The integrated digital control system actuates a
direct heating circuit and a storage tank charging circuit.
It can be extended in many ways with accessory components.
A detailed description is given in the documentation for the "ROTEX RoCon BF controller".
1
Clear text display
2
Setting: Configuration
3
Setting: Remote Param
4
Rotary switch
5
Setting: Info
6
Setting: Operating Mode
7
Setting: Set Temp Day
8
Setting: Set Temp Night
9
Setting: DHW Set Temp
10
Rotary button
11
Setting: DHW Reheating
12
Setting: Time Program
13
Exit key
14
Control panel RoCon B1
15
Mains switch
Fig. 6-1
Operating elements on the boiler control panel
Malfunctions are generally indicated by a fault code and
a clear text fault message on the display.
For troubleshooting instructions see chap. 10.
White:
Standard lighting, normal operating display.
Red:
Fault status, the boiler continues to operate with re-
strictions depending on the fault type.
Green:
Programming mode with operator authorisation.
Blue:
Programming mode with specialist authorisation.
You can find additional information and a detailed de-
scription in the "ROTEX RoCon BF" controller docu-
mentation. It is included in the scope of delivery for the
GCU compact.
Содержание GCU compact 315
Страница 81: ...13 x Notes 13 Notes...
Страница 82: ...13 x Notes...