6 DEVICE MENU
The following sections detail the Device Menu.
•
•
•
•
•
•
•
•
•
•
•
6.1 Cycle Operation
The Vent Levels and Variable Fan Levels features enable Cycle Operation. Cycle Operation means
that the fans operate at two levels, minimum and maximum. When the cycle is off, the fans run at the
minimum level. When the cycle is on, the fans run at maximum level.
To enable Cycle Operation:
1. In
Control > System Parameters > Var. Fan
, set the
Min Motor Speeds
(up to 4).
2. In
Control > System Parameters > Var. Fan
, set the
Fan Cycle
to High (default) or low.
o
High
: Maximum level is 100%; minimum level is user-determined.
o
Low
: Maximum level is user determined; minimum level is zero.
NOTE:
In Low, the maximum level is the
Minimum Motor Speed
.
6.2 Vent Levels
The SuperGuard provides up to 30 programmable ventilation levels.
NOTE:
When employing the Ventilation by Weight option, the On/Off times don't appear.
VENT LEVELS #01
#
12345678
on
Off
Diff
01
02
30
40
240
220
0
0
The usual way to program them is to start the first level with the least amount of air to be used.