17
SuperGuard and Piguard 80
|
1.04
The Minimum/Maximum Level menu sets the current absolute minimum and maximum ventilation levels
available. You have four minimum maximum level choices:
1. Min/Max by Growth Day
2. Min/Max by Time of Day
3. + 4 Soft Min/Max by Day or Time.
The third option provides the following: in extreme cold weather the minimum level ventilation might be
decreased. For that, the user utilizes the Soft Min level that operates according to outside or inside
temperature.
For example:
Target temperature = 74° F
Growth day = 1
Min Max Levels
System parameters -> Min/Max
Level control - DSFT (Soft Min by days)
Soft Min temp - Out (Control by outside temperature)
Soft Min Band - 4° F (Differential below heat temperature)
Soft Minimum By Time
From Time Min Cold Min Warm Max
8:00 1 7 25
20:00 3 5 23
By Time
From Time Min Max
8:00 1 21
20:00 3 21
Day
Min Cold
Min Warm
Max
1
1
10
30
3
4