SuperGuard and Piguard 80
Installation Manual and User Guide
110085
Страница 1: ...SuperGuard and Piguard 80 Installation Manual and User Guide 110085...
Страница 2: ...following cases i if all components of the product are not originally supplied by ROTEM ii the defect is the result of an act of nature lighting strikes electrical power surge or interruption of elect...
Страница 3: ...uard 8 4 Getting Started 9 4 1 10 Step Installation Guide 9 4 2 SuperGuard Keyboard 10 4 3 SuperGuard Main Screen 11 4 4 Hotkeys 12 5 SuperGuard Setup 14 6 CONTROL 16 6 1 Temp Curve 16 6 2 Min Max Lev...
Страница 4: ...igital Input 42 11 4 Analog Output 42 11 5 Variable Speed Fan 43 11 6 Sensor Definition 43 11 7 Curtain Setup 44 12 PIGUARD 45 12 1 Cold Start 45 12 2 Set Unit Number 45 12 3 Main Menu 45 12 4 Calibra...
Страница 5: ...f the procedures are not followed carefully WARNING Warnings alert you to potentially hazardous situations which if not avoided could result in death or personal injury NOTE Notes contain important ti...
Страница 6: ...use ground loop currents to flow which reduce reliability CAUTION The COM connection for communications is not the shield wire The COM RX and TX wires must connect to each other at all controllers 2 2...
Страница 7: ...ures and a 4x20 character LCD that provides display feedback on the programming and device status The SuperGuard communicates with Piguard units to access history collect events and alarms for each an...
Страница 8: ...tlook Alarm system for every Piguard unit Multi language support PC communication 3 3 2 85BPiguard Easy programming Programmable outputs Alarm system Large display Up to 3 temperature sensors Up to 8...
Страница 9: ...Cold Start Plug in the controller and hold the delete key DEL for a few seconds until a Cold Start sign will appear This action erases the memory completely and loads the default definitions 5 Super G...
Страница 10: ...Arrows Use the arrows to scroll a short press in any direction moves one notch D Round Arrows The Round Arrows key is used to scroll between options Yes No On Off and E Enter The enter key is a confir...
Страница 11: ...tunnel level CAUTION In case of an alarm a blinking message appears on any one of the main screens in addition to the siren Pressing 0 on the main screen when the alarm message is on directs you to th...
Страница 12: ...the temperature sensor T3 as OUT and therefore T3 presents the outside temperature On the right side you can see the temperature for entering tunnel ventilation mode T1 24 4 01 T2 25 1 AVG 22 9 T3 22...
Страница 13: ...us RELAY STATUS 01 R1 R2 R3 R4 R5 R6 R7 R8 EXTENSION RELAYS 9 This option shows active relays pressing 9 again opens the extension box s relay activity Hot key Round Arrow key History Temp This option...
Страница 14: ...Farm Center 1 PC Baudrate 4800 Total Rooms 5 Language Language English UNITS Temp F Press IN W C Other Units IMPER OUT TEMP From Room 1 TIME Time hh mm 12 06 PASSWORD Full Access 0 Read Only 0 Paramet...
Страница 15: ...Piguard controllers the SuperGuard begins a search to find the controllers defined LANGUAGE Select language TEMPERATURE UNIT Select between Celsius and Fahrenheit PRESSURE Select between Milibar IN W...
Страница 16: ...ow high alarm temperatures The controller creates a curve for each one and uses it as reference At midnight the program goes to the next day on the next row programmed There are up to 10 programmable...
Страница 17: ...mum level ventilation might be decreased For that the user utilizes the Soft Min level that operates according to outside or inside temperature For example Target temperature 74 F Growth day 1 Min Max...
Страница 18: ...s For example at 68 F the controller operates in level 5 Important When using Soft Min according to inside temperature there is a curve between min warm and min cold while decreasing levels When tempe...
Страница 19: ...re target during tunnel ventilation mode Low Alarm If static pressure drops below set point alarm will be active High Alarm If static pressure rises above set point alarm will be active Band Set band...
Страница 20: ...the offset heat temperature for any purpose Default 0 0 MIN MAX Curve If Yes Min Max table curve between the days Default NO Will work according to previous line until current day Level Control Four o...
Страница 21: ...s differential This number can be positive or negative To eliminate the effect of this parameter on tunnel exit enter a large positive number such as 90 0 Default 0 0 Exit Delay m Delay time after sat...
Страница 22: ...operation delay This is the Fan minimum speed to begin operation Default 30 6 6 31BControl Mode CONTROL MODE 01 Set Mode Normal Empty In this screen set the Control mode choose between Normal mode and...
Страница 23: ...ll circles represent continuous fan operation The half full circle represents cycle operations according to the on off time set for each stage A dot represents no operation at all The following table...
Страница 24: ...0 4 70 530 0 0 5 90 510 0 0 6 30 270 0 0 7 40 260 0 0 8 52 248 0 0 9 70 230 0 0 10 90 210 0 0 11 120 180 0 0 12 160 140 0 0 13 225 75 0 0 14 300 0 0 15 100 200 0 0 16 70 230 0 0 17 90 210 0 0 18 120...
Страница 25: ...g cycle operation The fan will operate at 100 at on time If set on 20 the fan will operate at 20 of the full power during off time in the cycle and increases to 100 during the on time 7 3 Curtain Leve...
Страница 26: ...irculation fans start if the difference between temperatures in different parts of the house is higher than the set differential The sensors that participate in this differential can be divided in to...
Страница 27: ...re goes back to the target the cooling process stops RH As long as the humidity Band are below this level the cooling operates Cooling stops only at humidity level band see figure below On Off sec On...
Страница 28: ...activate foggers When the temperature rises to the difference above target the fogger s process begins When the temperature goes back to target fogger s process stops RH As long as the humidity Band...
Страница 29: ...o the settings in this table and regardless of the conditions or other devices From HH MM Start time To HH MM End time To From Temperature From T To T The temperature range for extra system activity O...
Страница 30: ...80 F the temp diff is 1 and the temp band is 2 At 79 F the heater operates at minimum power according to minimum heat At 77 F and down the heater operates at 100 and between 79 F and 77 F there is a...
Страница 31: ...gures are accidentally entered it is possible to correct them by entering negative figures 8 2 Day Group DAY GROUP 01 Growth Day New Group Group No 2 Yes No 4 Day and Group keeps monitor the growth of...
Страница 32: ...emperature Example Outdoor comp Alarm then Alarm Outdoor Comp For example IF the pre set compensation is 2 F the outside temperature is 75 F and alarm is set to 76 F the controller adds the outside te...
Страница 33: ...resets the alarms ALARM RESET 01 Alarm Reset NO NOTE To reset the alarm press Enter and use the Round Arrows key to change from NO to YES 8 5 Version Use this window to check the controller s software...
Страница 34: ...er 1 00r01 OK ENTER Abort MENU Use the arrow keys to shift from NO to YES and press Enter to read from the data plug Before loading the setting you can view setting name and software version for this...
Страница 35: ...the data plug You can name your current configuration by using the arrow keys On the Gold Data Plug select NO SETTING to create a new setting or overwrite an existing one ENTER SETTING NAME Name Room...
Страница 36: ...01 DAY 1 2 100 MIN 76 0 75 0 AVG 78 6 77 0 MAX 80 0 80 0 9 2 51BHumidity HUMIDITY 01 DAY 1 2 100 MIN 55 0 55 0 AVG 60 0 60 0 MAX 67 0 66 0 Sensors Data collection for minimum maximum and average in t...
Страница 37: ...mption Change Change from previous day 9 5 Mortality MORTALITY 01 DAY 1 2 100 DAILY 0 1 TOTAL N A 1 Day Growth day Daily Daily mortality Total Mortality total since growth day one 9 6 Heater HEATER RO...
Страница 38: ...put failure 2 High Temp high temperature alarm 3 Low Temp low temperature alarm 4 Hum Sen Fail humidity sensor failure 5 Lost Comm lost communication 6 W Overflow water over flow 7 F Overflow feed ove...
Страница 39: ...s 1 Power up How many times the controller was turned on 2 Reset How many times the controller was reset 3 Cold How many cold starts were performed 4 Menu Which menu number has been changed The events...
Страница 40: ...number for each sensor in the Temp factor line Use the up and down arrow keys to select sensors 10 2 59BHumidity HUM CALIB 01 Humid factor 0 0 If needed calibrate the humidity sensor by using a very...
Страница 41: ...er as far as possible from heavy contactor boxes and other sources of electrical interference 11 1 Relay Layout RELAY LAYOUT 01 1 FUNCTION 01 02 Heater 1 Heater 2 Each relay can be defined to any of t...
Страница 42: ...for a temp sensor outside of the house NOTE Only sensor number 4 can be Out 11 3 64BDigital Input DIGITAL INPUT 01 OPTIONS Input 1 Input 2 Input 3 Water Feed None None Water Feed Aux Alarm There are t...
Страница 43: ...Heat Lamp 1 Heat Lamp 2 Curtain 1 Cool cell Ex System 1 Tun Curt Var Heat 1 Select the temperature sensors 1 4 to use for each function using the Round Arrows key to apply and remove check marks You w...
Страница 44: ...PEN CLS Curtain1 60 60 Curtain2 60 60 Curtain3 60 60 Curtain4 60 60 Tunnel 60 60 Inlet 60 60 Curtain Setup tells the controller how fast your curtains and side inlets move It needs this information to...
Страница 45: ...H Humidity in room rH t Target humidity day Growth day for the room The display alternates between the name and the figure 12 4 Calibration Temperature sensors are very accurate and most likely will n...
Страница 46: ...dity sensor A D counts Ai1 2 Analog inputs 1 to 2 Prs Pressure A D counts DG1 3 Digital inputs 1 to 3 12 6 74BTechnical Specifications Power Supply Mains Voltage Single phase115 230 VAC Main Fuse 315...
Страница 47: ...g from one building to another When splicing sensors to longer wires ensure that the splice is waterproof Use adhesive lined heat shrink marine grade to make waterproof connections Use a good compress...
Страница 48: ...les at bottom of the box and place cable holders 4 Place the required cables through the cable holders at the bottom of the unit Connect the wires according to the wiring diagrams 5 Make sure that you...
Страница 49: ...ram Figure 1 Metal Sheet Assembly Diagram Instructions 1 Drill holes in the three designated areas located in the back of the controller 2 Mount the controller using the three screws provided in the s...
Страница 50: ...SuperGuard and Piguard 80 1 04 50 12 11 79BSuperGuard Piguard Network Connection...
Страница 51: ...51 SuperGuard and Piguard 80 1 04 12 12 Piguard Wiring Diagram 1 Analog Output Power Potentiometer Relays Variable speed RHS 2...
Страница 52: ...SuperGuard and Piguard 80 1 04 52 12 13 81BCommunication Wiring Diagram...