3
4
2SA1016K
2SC2362K
2SA1209
2SC2911
2SA1376A
2SC3478A
2SD1953
2SA1667
2SC4381
2SA1492
2SC3856
Instruments : DC milli–voltmeter
Notes : Prior to Bias Adjustment, run about 5minutes
with rated output(8ohms) and warm up
Power Transistor and Heat Sink. Set input off.
Adjustment
Step
TP1
TP2
X-1240 PCB
VR601
VR602
X-1240 PCB
1
2
Coupling
Location
Adjust for
Adjust
DC milli–voltmeter reads 4mV
PCB Assembly
Case Outline
Содержание RB-1070
Страница 4: ...5 6 Schematic Diagram...