4

2SA1016K
2SC2362K
2SA1209
2SC2911
2SA1376A
2SC3478A

2SD1953

2SA1667
2SC4381

2SA1492
2SC3856

Instruments   :   DC  milli–voltmeter
Notes            :   Prior to Bias Adjustment, run about 5minutes 
           

with rated output(8ohms) and warm up 
Power Transistor and Heat Sink. Set input off.

Adjustment

Step

TP1

TP2

X-1240   PCB

VR601

VR602

X-1240   PCB

1

2

Coupling

Location

Adjust for

Adjust

DC milli–voltmeter reads 4mV

PCB Assembly

Case Outline