background image

Device in Case of Power Failure

To use if needed

DC power cord 

1.

2.

9V

9V

9V

9V

APP Control Guide (Dream Motion)

Download free to control the bed from a smartphone or a tablet.

Please follow the instructions for use in the APP.

IOS

ANDROID

Open the APP Store, search for the keyword "Dream Motion" to download the app.

Open the Google Play to search for the keyword "Dream Motion" and download the app.

Dream Motion

Dream Motion

Device with 2 9V batteries

08

09

Head 

Motor

Foot

Motor

Neck

Motor

Lumbar

Motor

Power

USB

Foot

Massage

Head

Massage

LED

APP

Sync

HEAD UP/DOWN BUTTONS
Press and hold to lift or lower the HEAD section.

FOOT UP/DOWN BUTTONS
Press and hold to lift or lower the FOOT section.

NECK UP/DOWN BUTTONS
Press and hold to lift or lower the NECK section.

Adjustment

• Make sure the remote control is paired with the base.
• Check that the power cord is plugged into a working and grounded 
  electrical outlet. Unplug the power cord from the outlet. After 30 
  seconds, plug it back in. Press any button on the remote control 
  and hold until light on the remote control turns on.

• Make sure the remote control is paired with the base.
• Check that the power cord is plugged into a working and grounded 
  electrical outlet. Unplug the power cord from the outlet. After 30 
  seconds, plug it back in. Press any button on the remote control 
  and hold until light on the remote control turns on.
• Check that the surge protection device or electrical outlet is not 
  defective. Test the outlet by plugging in anotherworking appliance.

• Your base may be obstructed, preventing smooth operation. Remove 
  obstructions from around and under the base.
• Check that the head section is not too close to the wall.
• If a headboard is installed, check that it is not too close to the edge 
  of the mattress. Make sure there is enough distance between the 
  headboard bracket and themattress.

• Check the batteries in the remote control. Replace with new batteries, 
  if necessary.
• Make sure that you are following the duty cycle of the motors. Do 
  not operate for more than two minutes over a 20-minute period or 
  approximately 10% duty cycle.
• Press the lift buttons firmly andaccurately.
• The remote control may be experiencing common radio frequency 
  interference from other radio transmitting devices. Wait several 
  seconds and then try pressing the lift buttons again.

• This is normal. The lift motors click when they are engaged. No 
  action is required.

The adjustable base does not respond
when the remote control is used. 
Remote control led light is on and 
appears to be normal.

None of the features or functions 
of the base activates.

Head or foot lift function works to 
lift the base, but it does not return 
it to the flat position.

Head or foot lift function has minor 
interference during operation.

A clicking noise is heard under the 
base when raising or lowering the 
sections.

Excessive massage motor noise.

• If the base is located on hard surface flooring, place carpet pieces 
  or rubber pieces (not included) under each leg.
• Using the remote control, raise the head, foot or neck section slightly 
  to realign the lift/lower mechanisms with the base support platform.
• Make sure that your base is not positioned against a wall, nightstand, 
  or other object that may cause the vibration or noise.
• If the base is installed over a base frame, make sure that the massage 
  motors arenotcausing the base frame (or base frame components) 
  to vibrate.
• Make sure that the headboard attachment hardware isproperly 
  tightened (if used).

Troubleshooting

When there is an electric power failure, the included device and two batteries 9V 2.0A (not included) can be 
used to flatten the base.
(1) Put the batteries in the device.
(2) Unplug the power cord from the outlet and plug the power cord into the device.
(3) Adjust the base.

How To Reset

STEP 1

Unplug 

adjustable base

 from the power source. 

STEP 2

Plug 

adjustable base

 back into the power source after 60 seconds.

STEP 3

Automatic reset is completed. 

If the adjustable base fails to operate, search for the symptoms and possible solutions below.

Содержание GEMINI 300M 2.0

Страница 1: ...GEMINI 300M 2 0 Rev 1 0 ROTEC INTERNATIONAL 123 RUE DE L GLISE BAIE DU FEBVRE QC CANADA J0G 1A0 Owner s Manual Adjustable Bed Base All Rights Reserved...

Страница 2: ...1 Use caution when there are liquids in or around the base to ensure no spilling occurs In case of spillage stand in a dry clean area of the oor and unplug the base immediately Clean up the spill and...

Страница 3: ...pen the carton while the base is in the flat position 3 AAA batteries for remote control Two people are required to set up the adjustable bed base 1 2 Base Installation Guide Open the box take out all...

Страница 4: ...Supply AC Power Source Connect the DC power cord to the power supply uncoil the AC power cord and then connect it to the AC power source Connect the connectors as illustrated 6 DONE Insert 3 AAA batte...

Страница 5: ...eans the two bases can be synchronized with one remote control NOTE To control the two bases separately without removing the sync cord open the control remote battery box and flip the switch to the A...

Страница 6: ...new batteries if necessary Make sure that you are following the duty cycle of the motors Do not operate for more than two minutes over a 20 minute period or approximately 10 duty cycle Press the lift...

Страница 7: ...ollowing the purchase date Five 5 Year Warranty Electric and Massage Motors Our product has a five year full replacement warranty on parts labor and authorized transportation on the electric and massa...

Отзывы: