BRP-Rotax
INSTALLATION MANUAL
MECHANICAL INTERFACES
Throttle body
Interface Parameter
Min.
Max.
Tightening torque
4 Nm (3.32 lb ft.) (suitable
for flexible cable), 1.5 mm
(0.06 in.) steel rope or sin-
gle-strand wire
—
Cable travel
65 mm (2.56 in.)
—
Actuating force
7.5 N (1.69 lb ft.)
20 N (4.5 lb ft.)
Max. permissible actuating force
—
20 N (4.5 lb ft.)
Connection
: Set screw M6x12 mm
Intercooler
Figure 6.3: Intercooler: Connection and dimensions
To attach the intercooler within the airframe design four suitable fixation points are avail-
able and M6 screws must be used.