SETTING OF THE EXHAUST VALVE TIMING
Tools required:
• Allen key 4 mm or Socket wrench 8 mm
The opening time of the exhaust valve is set in the ECU and depends on the engine
speed. However, the ECU allows two different modes of the exhaust valve opening. These
can be selected by connecting an additional cable to the cylinder head cover.
ATTENTION
The ground wire must be continuously connected.
This is important for the general function of the engine.
Variant 1: Additional cable on battery ground
A:
See
The additional cable is
NOT
attached to the ground wire. The control of the exhaust valve
timing is activated at 9100 rpm.
NOTE
Isolate the additional cable with an electrical/insulating tape to the ground wire so
that a possible contact with the engine ground does not affect the function.
B:
See
The additional cable is attached to the ground wire. The control of the exhaust valve timing
is activated at 8800 rpm.
Effectivity: 125 MAX DD2 evo
Page 5
Edition: March 01 2021
Содержание 125 DD2 MAX EVO
Страница 1: ...OPERATOR S MANUAL 125 DD2 MAX EVO KART ED 03 2021 PART NO 297732 ROTAX KART COM...
Страница 4: ...Page 2 Edition March 01 2021 Effectivity 125 MAX DD2 evo NOTES BRP Rotax Operators Manual...
Страница 12: ...Page 6 Edition March 01 2021 Effectivity 125 MAX DD2 evo NOTES BRP Rotax Operators Manual...
Страница 20: ...Page 8 Edition March 01 2021 Effectivity 125 MAX DD2 evo NOTES BRP Rotax Operators Manual...
Страница 41: ...BRP Rotax Operators Manual Figure 3 15 Adjusted Effectivity 125 MAX DD2 evo 3 Page 21 Edition March 01 2021...
Страница 42: ...Page 22 Edition March 01 2021 Effectivity 125 MAX DD2 evo NOTES BRP Rotax Operators Manual...
Страница 58: ......