Compatibility: The SAK-25 Wire to RF Transmitter, with Magnetic Contact Sensor, is compatible with a variety of
Rosslare's receivers and panels, in 433.92 or 868.35 MHz
Default 3-ID’s Independent
Magnet not functioning
Channel 1 (PIR Normally Open)
- 3 -
Local Programming the operation of the SAK-25 is available locally using the push buttons S1 and S2 and the Tri Color LED.
1) Press both buttons at the same time and release when the LED is solid orange to enter the menu
2) You will see the current mode of the ID Code settings upon release of both of the buttons.
Mode 1: Built-in Magnetic Sensor Enabled
Mode 2: Built-in Magnetic Sensor Disabled
3) Press S2 to toggle the current setting
Toggling from Mode 1 to Mode 2
If the mode was Mode 1 (Flashing Red) pressing S2 will toggle the mode to Mode 2.
Press both S1 and S2 together to exit the menu.
Toggling from Mode 2 to Mode 1
If the mode was Mode 1 (Flashing Red) pressing S2 will toggle the mode to Mode 2.
Press both S1 and S2 together to exit the menu.
SOLID Green MENU for Enabling or Disabling the Internal Built in Magnetic Contact Sensor
Solid Orange LED MENU
S2
S1
Solid Red LED
Flashing Red LED
S2
S2
Solid Red LED
Flashing Red LED
Solid Red LED
Flashing Red LED
Bypass Internal
Magnetic Sensor
Check this box to
Bypass a local
magnetic sensor
Restore Internal
Magnetic Sensor
Check this box to
activate automatic
restore signal after 2
seconds for Magnetic
Sensor
Input 1
Programming
Input 2
Programming
Select for 3
Channels same
ID Code or
Separate ID
Codes for RF
Upload Button
Retrieves the current
settings from a
connected unit to
the PC Screen
Tools Menu
Options
Language
Help Menu
Help and
Instructions
File Menu
Upload
Download
Reset
Exit
Download
Button
Programs a
connected unit with
the selections on the
PC Screen
Reset Button
Restores the Screen
settings to factory
default mode.
Programming SAK-25
Using PC Software
Utility (Version 1.2.0)
Y o u c a n d o w n l o a d t h e P C
Software utility from Rosslare's
Software Download Site on the
world wide web. For an updated
pa s s w ord t o t he s i te , ple a s e
contact your authorized Rosslare
Representative.
1) Download the software or install
it from the CD-Rom by following
the instructions.
2) Connect one side of the
Rosslare RS-232 Data cable to
the COM port of the PC.
3) Plug the other end, a 3-Pin
connector, of the RS-232 Cable
to the SAK-25 product,
according to the connector
polarity.
4) Start the utility software on the
PC. The following screen with
appear.
5) Provide power to the SAK-25
unit.
6) Make your programming
selections and Upload or
Download. You have
ONLY 20
seconds
to make a selection
before the SAK-25 unit
switches to regular operation
mode and cannot be
programmed.
SA-25 Instruction Manual - Version 1.0 (Page 3/4)