Rosslare SA-02N Скачать руководство пользователя страница 1

SA-02N 

Supervised Wireless Magnetic Contact Sensor 

Installation Manual

 

1.

 

General Description 

The SA-02N Supervised Wireless Magnetic Contact Sensor is a high-

performance intrusion sensor, developed with the highest level of 
technology to make it ideal for residential and commercial applications. 

1.1

 

Standard Features 

 

Supervisor 

 

Case and Back Tamper Detectors 

 

ASIC and Microprocessor Technology 

 

Up to 3-year battery life with SPS 

 

Ultra-low current consumption 

 

Readily replaceable 3.6 V – 1/2 AA Lithium battery 

 

SMD component technology 

 

LED Test Function 

Figure 1: SA-02N 

 

2.

 

Technical Specifications

2.1

 

Electrical Characteristics 

Battery 

CR123A 3V 1400 mAh (low battery signal when V = 

2.5 V) 

Current 

Standby – 3 to 8 uA; Transmit – 5 mA 

Pulse Count 

Fixed at single pulse 

Detect Range 

Sensitivity of up to 2 cm from magnet 

Alarm Transmit 

One second 

Indication 

LED EN/DIS 

2.2

 

Physical Characteristics 

Dimensions (H x W x D):  

87 x 35 x 25 mm (3.5 x 13.8 x 1 in.) 

Weight 

37 g (1.30 oz) without battery 

Standards 

FCC, CE, EN 50131-2-6, EN 50131-6, EN 50130-5, 

EN 50130-4, Security Grade 2, Environmental Class 
II 

 

2.3

 

Environmental Characteristics 

Operating Temperature 
Range 

-20°C to 50°C (-4°F to 122°F) 

Operating Humidity 
Range 

Up to 95% (non-condensing) (max.) 

RF Frequency 

Available in 433.92 MHz or 868.35 MHz, with 1 m 
Watt 

Installation 

Indoor 

Magnet 

Standard magnet with plastic housing and wall 

spacer, adjustable height 

Tamper Switch 1 

Detects removal of Magnetic Contact Sensor Front 
Cover (protected by case tamper switch) 

Tamper Switch 2 

Detects removal of Magnetic Contact Sensor from 

the wall or from corner mount (protected by rear 
tamper switch) 

Supervisor 

The supervisory signal is routinely transmitted to the 

panels every 20 minutes, advising the Tamper 
Status, Battery Status, and Event Activation Status to 
the panel 

3.

 

Installation Recommendations 

The SA-02N Magnetic Contact Sensor detects the opening and closing 

of doors and windows, and transmits this information to the receiver 

panel. 

 

AVOID

 placing the Magnetic Contact Sensor near strong magnetic 

or electrical fields other than the magnet with which it is intended 

to be used; otherwise, performance may be affected and false 
alarms may occur. 

 

AVOID

 mounting on or near large metal surfaces and multiple 

concrete/steel walls, as this may interfere or block the wireless 

signals. Make sure to test the range from any location by using the 

RF Test Procedure to ensure reception. 

 

Install the magnetic contact sensor on windows or doors that 
have firm hinges and firm locking action to prevent false 
alarms associated with wind or bumping. 

4.

 

Installation Instructions 

4.1

 

Selecting the Location 

The location and mounting of the SA-02N affects both the 

transmission range and the wear and tear of the transmitter. Preferably 

the transmitter should be installed as close as possible to the receiver, 
and mounted in a high location so that the transmission has less 

interference. 
To select the location: 
1.

 

Select a door or window within a room or hallway that best 
matches the criteria in Section 

 

3 (see Figure 2). 

2.

 

Make sure that the Magnetic Contact Sensor is mounted on a 
sturdy, non-vibrating door or window frame. 

 

Following this instruction reduces bumping and vibration 
effects on the sensor and extends the life of the product. 

3.

 

Perform the RF Test from the proposed mounting location to 

ensure that the sensor can be received. 

4.

 

Select the appropriate height for the magnet assembly that suits 

the location of the sensor. 

Figure 2: 

Selecting a Location

 

 