3. Enter the password.
•
Use the default password (12345678) when you log in to the BLE-Admin application for the first time.
•
It is highly recommended that you change the password (see step 4).
4. On the main screen, configure the following:
Option
Remarks
Reader Name
Assign name to selected door reader
Password
Change password
5. Tap Set Configuration and configure the following:
Parameter
Options
Remarks
Protocol
Wiegand, OSDP, OSDP-SC, Clock and Data
Wiegand: 26, 32, 34, 40, 56, 64 bit
26 bit (default)
Toggle to select Reverse
OSDP-SC: Install mode (read/write)
OSDP addresses: 0-31
13 (default)
Credentials reading
standards
125 KHz EM (ASK)
125 KHz (FSK)
ISO 14443A
ISO 14443B
ISO 15693
BLE Credential
You can select multiple credentials.
All standards are selected by default.
125KHz (FSK) supports
Wiegand 26, 32, 34, 35, 37,
40, 48 bit.
Multi-Smart™ Readers Installation & User Guide