background image

ME-14 

Compact Single Board Self-Powered Enclosure 

Installation Manual

 

1.

 

Introduction 

The ME-14 is a simple plastic enclosure suited for a singular PCB and 

Rosslare’s BT-16 backup battery. The ME-14 boasts two tamper triggers, 
one for the back case detecting wall detachment and one for the casing 

itself detecting attempts to open the encasement. 
The enclosure is suitable for any one of Rosslare’s ExpansE units, EXP-

1032 Network Controller known as an MU, and the various EUs: EXP-

2024 Dual Reader Door Unit, EXP-2016 16-Relay Elevator Control Unit, 
EXP-2088 – 8-Input/Output Interface, as well as Rosslare’s MD-W11 

Wireless Access Control Door Interface. 

Figure 1: ME-14 

 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics 

Power 

From External source 

Backup battery 

BT-16 

 

 

The backup battery has no external power source and has no 
charger available, once the backup battery is depleted it needs 
to be replaced. 

2.2

 

Environmental Characteristics 

Operating Environment 

Indoor use 

Operating Temperature Range 

-10°C to 50°C (14°F to 122°F) 

Operating Humidity Range 

0 to 95% (non-condensing) 

2.3

 

Physical Characteristics 

Dimensions (H x W x D) 

130 x 180 x 40 mm (5.1 x 7.1 x 1.6 in.) 

Weight 

200 g (7 oz.) 

3.

 

Installation 

3.1

 

General 

The ME-14 is designed for easy installation. Only a few steps are required 
to wire the chosen PCB, install it in the case and mount it onto the wall. 
To install the ME-14: 
1.

 

Unscrew the three Philips-head screw located on the bottom of the 
unit and push the safety latches to “unlock”. 

2.

 

Open the case upwards in accordance with the notches located on 

the top of the case. 

3.

 

Use the designated notches to install the PCB and backup battery 

into the ME-14 case. 

4.

 

Wire the unit being installed according to the wiring instructions as 

explained in the relevant installer manual. 

5.

 

Mount the PCB into the designated area; align the PCB holes with 

those of the encasement. 

6.

 

Mount the backup battery (optional) onto the designated location on 
the top right side of the encasement. 

Figure 2: ME-14 Assembly 

 

3.2

 

Mounting the ME-14 

Select an area for mounting the ME-14, and ensure the location is flat, 
for perfect mounting of the unit. When using the ME-14 with the MD-

W11, make sure to mount the ME-14 in a location suited for wireless 

reception.  

To mount the ME-14: 
1.

 

Using the holes dimensions and locations shown in Figure 2, drill 

holes in the wall. Alternatively, use the ME-14’s back plate as a 
template. 

2.

 

Insert masonry anchors into the drilled holes. 

3.

 

Mount the PCB into the designated area; align the PCB holes with 
those of the encasement. 

Отзывы: