Connection and Configuration
16
MD-N32 Installation and Operation Manual
Figure 5: AS-IP01 Configuration Utility – Search Button Results
It is not possible to run two sets of AS-IP01 simultaneously on
the same PC or on the same network. It is also not
recommended that AS-IP01 be run simultaneously with some
software applications either based on Microsoft
®
Visual Basic 6
or featuring TCP/IP support, since the AS-IP01 may malfunction.
For example, it is not recommended to run AS-IP01 on the same
PC and at the same time as Rosslare’s AxTraxNG™ software.
4.
Select the MAC Address of the MD-N32 unit that is connected to
the applicable networked unit.
5.
In the Network section, in the
Local IP
and
Local Port
text boxes,
enter the first IP Address and port number (1000 recommended)
supplied by your network administrator.
6.
In the
Subnet
text box, enter the supplied subnet.
7.
In the
Server IP
text box, enter the second IP address and port
number (1000 recommended).
8.
In Modes, select either
Client
or
Server
, as required.