Page 20
07/04
AC-Q41H
Programming the AC-Q41H
Programming the AC-Q41H is done solely via the unit's keypad
driven Programming Menu System. To reach the Programming
Menu System the AC-Q41H must first be placed into Programming
Mode. See "Entering Programming Mode" on Page 22 for more
information.
During the AC-Q41H's manufacturing process certain codes and
settings are pre-programmed. These settings are the called the
"Default Factory Settings".
The table below shows the names of all the AC-Q41H menus. It
also shows of all the AC-Q41H's default factory codes and settings.
Programming Menu
2580
Change Open Code
1
0852
Change Auxiliary Code
2
1234
Change Program Code
3
3838
Change Normal / Secure Code
4
Change Normal / Bypass Code
5
0004
Change Lock Strike Release Time
6
2004
Define Auxiliary Inputs / Outputs
6
3000
Enable or Disable Keypad Heater 6
Enroll Proximity Cards, PIN Code or both.
7
Delete Proximity Cards or PIN Code
8
Code Assignment with Strike/Auxiliary
9
Return to Default Factory Setting
0
You will find a complete description and instructions for each of the
above menu items on the following pages.
Menu Description
Factory
Settings
Menu
Number
Page 21
07/04
AC-Q41H
BL-D40 External Sounder
The BL-D40 External Sounder is designed to operate indoors and
installed within the premises to be secured. The Sounder can be
powered by 16 to 24V DC power supply or by 16 to 24V AC from a
transformer.
The BL-D40 is capable of emitting four different types of alerts both
audible and visual; Bell, Door Chime, Siren, and Strobe Light.
1)
The Bell always sounds when the controller's door bell button
is pressed.
2)
The Door Chime can be programmed to sound whenever a valid
code is entered.
3)
The Siren can be programmed to sound when the case of the
controller is tempered i.e. opened or when the controller is
removed from the wall. The controller can also program the
length of the Siren time in the BL-D40.
The Controller communicates with the BL-D40 using a coded
proprietary Rosslare communications protocol. This provides a
secure link between the Controller and the BL-D40.
If the BL-D40 receives any unrecognized codes on its
communication line or communication between the controller and
the BL-D40 are severed, the Strobe will flash repeatedly until the
communication problem has been resolved.