Rosslare EX-07 Скачать руководство пользователя страница 2

 

3.

 

Installation 

3.1

 

Selecting an Area for Installation 

You need to select the best physical location to install the EX-07/EX17. 

The EX-07/EX-17 REX button has a face plate attached to an inlay that 

is imbedded in a wall with all of its wiring. The EX-07/17 should be 

connected to additional equipment in the same room. 

To select a physical location: 

1.

 

Select a flat wall in close proximity to the door or item the REX 

button will control. 

2.

 

Ensure that there are no iron beams, door frames, or other 

obstructions that would prevent the insertion of the inlay in the 

wall. 

3.

 

Stick the mounting plate provided on the wall to ensure quick and 

easy installation of the product. 

4.

 

Mark the dimensions of the inlay on the wall: 
70 x 38 x 27 mm (2.8 x 1.5 x 1.1 in.) 

Figure 3 provides a view of the back of the inlay. 

Figure 3: Inlay Back View 

 

3.2

 

Mounting the REX Button 

To mount the REX button: 

1.

 

Make a hole in the wall measuring the required dimensions, adding 

0.5 cm (1/8”) on all sides for the gang box to slide in smoothly. 

2.

 

Unscrew the cover on the small box containing the jumpers and 

potentiometer. 

3.

 

Using a small screwdriver, set the time on the potentiometer. 

 

Turning the timer clockwise all the way sets the timer for one 

second. Turning the timer counter-clockwise all the way sets the 

timer for 60 seconds. 

4.

 

Connect the wires as described in Sectio

 

3.3. 

5.

 

Set the jumper connections located on the bottom right side of the 

inlay box (see Sectio

 

4) 

6.

 

Screw the sealed cover back on the small box containing the 

jumpers and potentiometer. 

7.

 

Test the REX button before screwing the inlay to the gang box (see 

Sectio

 

5)

8.

 

Place the inlay with face plate in the gang box, making sure screw 

alignment is correct and the face plate lies flush against the wall. 

9.

 

Insert screws in the face plate and screw tightly to ensure a water 

tight seal that protects the inner wiring. 

3.3

 

Wiring Information 

A 10-wire cable is embedded in the back inlay. 

 

Connect this product to 12 to 24 VAC/VDC connections using the 

white and red wires. Make sure that, if needed, the unit is 

grounded (GND) correctly. 

To wire the unit correctly, refer to Table 1. 

Table 1: Wiring Color 

Wire Color 

Connection 

White 

V IN (12-24 VAC/VDC) 

Red 

V IN (12-24 VAC/VDC) 

Brown 

N.C. 1 

Purple  

COM1 

Grey 

N.O. 1 

Orange 

N.C. 2 

Blue 

COM2 

Yellow 

N.O. 2 

Green 

Input 

Black 

Ground/Shield 

 

 

The COM must be connected to the adjacent N.C. or N.O. relay. 

4.

 

Jumper Settings 

The EX-07/EX-17 has 8 internal jumpers (Figure 4)

Figure 4: Jumpers 

 

These are connected to enable the following various features: 

 

Setting the relay mode (JP1) 

 

Setting the LED behavior (JP2, JP3) 

 

Setting the LED color mode (JP4) 

 

Setting color fading mode (JP5) 

 

Setting the factory programming mode(JP6) 

 

Setting the buzzer mode (JP7) 

 

Setting the blink mode (JP8) 

If the black cover is on the jumper, the jumper is Short (S). If the black 

cover is off the jumper, the jumper is Open (O). 

Отзывы: