Installation
AYC-F/G/M60 Series Installation and Programming Manual
13
3.
Installation
Installation of an RFID reader adjacent to metallic surfaces
might alter the reader’s specifications. To diminish this
interference, use a plastic spacer when mounting the reader.
Before starting, select the location to mount the unit. This location
should be at shoulder height.
3.1
Mounting
Before starting, select the location to mount the unit. This location
should be at shoulder height.
To mount the unit:
1.
Peel off the back of the self-adhesive installation template and
attach the template to the required location.
2.
Using the template as a guide, drill holes according to how you
want to mount the unit (Figure 1).
Figure 1: Drilling and Mounting Holes
AYC-F60
AYC-G60
AYC-M60
3.
Drill a 10-mm (7/16”) hole for the cable. If the surface is metal,
place a grommet or electrical tape around the edge of the hole.
4.
At the bottom of the unit’s case, remove the screw.
5.
Carefully remove the snap-off front cover of the unit to reveal the
screw holes.