Wiring
AY-U9xxBT Installation and User Manual
11
3.
Wiring
The units are supplied with a 5 m (16.4 ft) 10-conductor pigtail with exposed wires
coated with solder (see Figure 5).
Figure 5: Wiring Colors
To connect the unit as a reader to an access control unit:
1.
Select the appropriate connections according to Table 1.
2.
Prepare the controller cable by cutting its jacket back about 3 cm (1¼") and
strip the insulation from the wires about 1.3 cm (½").
3.
Splice the reader’s pigtail wires to the corresponding controller wires and cover
each joint with insulating tape.
Table 1: Wiring the Unit as a Reader to a Control Panel
Wire Color
Output
Red
Power
Black
Ground
Green
Data 0 / Data / C2
White
Data 1 / Clock / C1
Orange
Green LED Control
Brown
Yellow LED Control
Purple
OC Output*
Yellow
Hold/Trigger Control
Blue
RS-485 - A / OSDP*
Gray
RS-485 - B / OSDP*
* For future use
4.
Trim and insulate the ends of all unused conductors individually. Do not short
any unused wires together.
•
The individual wires from the reader are color coded according the Wiegand
standard.
•
When using a separate power supply for the reader, this supply and that of the
controller must have a common ground.
•
The reader’s cable shield wire should be preferably attached to an earth ground, or
a signal ground connection at the panel, or the power supply end of the cable. This
configuration is best for shielding the reader cable from external interference.