AY-x6255 Family
CSN SELECT Smart Card Readers (Rev. A)
Installation and User Manual
1
1.
Introduction
The CSN SELECT AY-x6255 is a family of multi-credential technology
contactless smart card readers for use in access control system
solutions. CSN SELECT readers have the capability to read the Card
Serial Number (CSN) from many smart card RFID Standards
implementations. The following list shows the credential technologies
for which we have confirmed compatibility:
ISO14443A – MIFARE® Ultralight® Nano / EV1/ C, MIFARE
Classic® / Classic EV1, MIFARE Plus® S / SE / X / EV1, MIFARE
DESFire® EV1 / EV2, NFC N-TAG / Card Emulation
ISO14443B – China National ID
ISO15693 – HID® iClass®, PicoPass, iCode, LEGIC
ISO18092 – SONY® FeliCa® (Hong Kong Octopus)
This list is continuously updated. For the latest compatibility list,
contact your sales representative.
The standard readers output the Wiegand CSN data in 26-bit format.
Other Wiegand formats are available upon request.
1.1
Installation Kit
The installation kit consists of the following items to be used during
the installation procedure:
1 self-adhesive mounting label template
2 mounting screws and 2 screw anchors
1 pin Torx key tool
1 pin Torx security screw
AY-K6255
AY-L6255
AY-H6255
AY-M6255
AY-Q6255
2.
Technical Specifications
2.1
Electrical Characteristics
Power Supply Type
Regulated
Operating Voltage Range
8 to 16 VDC
Current @ 12 V
AY-K/L6255: Standby: 55 mA, max: 80 mA
AY-H/M6255: Standby: 75 mA, max: 110 mA
AY-Q6255: Standby: 100 mA, max: 150 mA
Read Range*
AY-K6255/AY-Q6255: 5 cm (2.0 in.)
AY-L6255: 7 cm (2.9 in.)
AY-H/M6255: 9 cm (3.5 in.)
LED/Buzzer Controls**
Dry Contact, N.O.
Tamper Output**
Open collector, active low, max. sink current
16 mA
Maximum Cable Distance
to Controller
Wiegand: 150 m (500 ft) with 18-AWG cable
OSDP (RS-485): 1,200 m (4,000 ft) with 2x2 18-
AWG twisted shielded cable
* Measured using a Rosslare MIFARE Classic EV1 (ISO Card). Read range with
other credential technologies may vary. Range also depends on electrical
environment and proximity to metal.
** Control lines are factory programmable and can be custom configured upon
request.
2.2
Environmental Characteristics
Operating Temp. Range
-35°C to 66°C (-31°F to 150°F)
Operating Humidity Range
0 to 95% (non-condensing)
Outdoor Usage
Weather-resistant, UV-resistant, meets IP65,
epoxy-potted, suitable for indoor and outdoor
use
2.3
Physical Characteristics
Dimensions
(H x W x D)
AY-K6255: 80.5 x 40.5 x 14.7 mm (
3.2 x 1.6 x 0.6
in.)
AY-L6255: 145.0 x 43.0 x 22.3 mm (
5.7 x 1.7 x 0.9
in.)
AY-H6255: 110.7 x 75.0 x 17.0 mm (
4.4 x 3.0 x 0.7
in.)
AY-M6255: 89.5 x 88.5 x 16.9 mm (
3.5 x 3.5 x 0.7
in.)
AY-Q6255: 120.0 × 76.0 × 21.5 mm (4.7 x 3.0 x 0.9 in.)
Weight
AY-K6255: 73 g (2.6 oz)
AY-L6255: 130 g (4.6 oz)
AY-H6255: 177 g (6.2 oz)
AY-M6255: 167 g (5.9 oz)
AY-Q6255: 410g (14.5 oz)
3.
Wiring Instructions
The units are supplied with a 10-conductor 18” (46-cm) pigtail.
To connect the reader to the controller:
1.
Prepare the reader cable by cutting its jacket back about 3 cm
(1¼”) and strip the insulation from the wires about 1.3 cm (½").
2.
Prepare the controller cable by cutting its jacket back about 3 cm
(1¼") and strip the insulation from the wires about 1.3 cm (½").
3.
Splice the reader’s pigtail wires to the corresponding controller
wires (see Table 1) and cover each joint with insulating tape.
4.
If the tamper output is being utilized, connect the purple wire to
the correct input on the controller.
5.
Trim and cover all unused conductors.
•
The individual wires from the reader are color coded according the
Wiegand standard.
•
When using a separate power supply for the reader, this supply and
that of the controller must have a common ground.
•
The reader’s cable shield wire should be preferably attached to an
earth ground, or a signal ground connection at the panel, or power
supply end of the cable.
Table 1: Wiring
Wire Color
Function
Red
Power
Black
Ground
Green
Data 0 / Data
White
Data 1 / Clock
Orange
Green LED control
Brown
Red LED control
Purple
Tamper Output
Yellow
Buzzer control
Blue
RS-485 - A / OSDP*
Gray
RS-485 - B / OSDP*
* RS-485 is used for firmware update. OSDP function is available only for the