Technical Specifications  

AY-Q6x60 Series Installation and Programming Manual 

35 

6.

 

Technical Specifications 

Electrical Characteristics 

Input Voltage 

5 to 16 VDC 

Absolute Maximum Voltage 

(non-operating) 

18 VDC 

Input Current @ 12V 

AY-Q6260: 

Standby: 110 mA, Maximum: 190 mA 
AY-Q6360: 

Standby: 160 mA, Maximum: 240 mA 

LED/Buzzer Control Input 

Dry Contact, N.O. 

Tamper Output 

Open collector, active low, 30 mA 

maximum sink current 

Operational Characteristics 

Maximum Controller Cable 

Distance  

150 m (500 ft) using 18 AWG cable 

Proximity Read Range* 

20 mm (0.8 in.) 

Operating Frequency 

13.56 MHz 

Transfer Bit Rate 

106 Kbits per second 

Output Indicators 

One tri-colored LED buzzer 

Card Compatibility 

MIFARE

 

 and all ISO14443A-3 cards 

Card Transmit Formats 

Programmable 

Keypad Transmit Formats 

AY-Q6260: None 
AY-Q6360: User programmable 

Transmission Formats 

Wiegand and Clock & Data 

*  Measured using a Rosslare proximity card or equivalent. Range also 

depends on electrical environment and proximity to metal

 

Содержание Anti-Vandal MIFARE AY-Q6 60 Series

Страница 1: ...AY Q6x60 Series Anti Vandal MIFARE Contactless Smart Card Sector Readers Installation and User Manual Models AY Q6260 AY Q6360 AY Q6260 AY Q6360...

Страница 2: ...l property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL...

Страница 3: ...ion Modes 13 3 2 Configuration Card Structure 14 3 3 Configuring Settings 14 3 4 Configuration Procedure 15 4 How to Use the Reader 16 4 1 Normal Operation 16 4 1 1 Card Serial Number Mode 16 4 1 2 Se...

Страница 4: ...oximity Card Transmission Format 28 5 6 1 Proximity Card Transmission Formats 29 5 7 Changing the Programming Code 32 5 8 Changing the Facility Code 32 5 9 Setting the Backlight Behavior 33 5 10 Retur...

Страница 5: ...List of Figures AY Q6x60 Series Installation and Programming Manual v List of Figures Figure 1 Drilling Mounting Holes 10...

Страница 6: ...List of Tables vi AY Q6x60 Series Installation and Programming Manual List of Tables Table 1 Wiring the Reader to the Controller 11 Table 2 Programming Menu 20...

Страница 7: ...f the system with the maximum number of functions including future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you...

Страница 8: ...ers they receive to an access control system The readers can also check the validity of cards before scanning them When checking readers only send card information to the access control system from ca...

Страница 9: ...ber only MIFARE Classic 1K MIFARE 4K MIFAREDESFire card serial number only 1 2 Box Content Before beginning verify that all of the following is in the box If anything is missing please report the disc...

Страница 10: ...ht To mount the unit 1 Peel off the back of the self adhesive installation template and attach the template to the required location 2 At the bottom of the unit s case remove the screw 3 Remove the co...

Страница 11: ...rx screw A Torx security screw tool is provided to tighten the security Torx screw 2 2 Wiring The units are supplied with a 10 conductor 46 cm 18 in pigtail with exposed wires coated with solder The r...

Страница 12: ...cm 3 Splice the reader s pigtail wires to the corresponding controller wires and cover each joint with insulating tape 4 Trim and cover all unused conductors To shield the cable from external interfe...

Страница 13: ...oftware AS B01 must be used to create configuration cards 3 1 Operation Modes The reader operates in two modes Card Serial Number mode The reader scans every card and sends each card s serial number t...

Страница 14: ...y MIFARE 1K and MIFARE 4K cards are supported MIFARE Ultralight and DESFire cards are non functional 3 2 Configuration Card Structure MIFARE smart cards are split into multiple sectors on a MIFARE 1K...

Страница 15: ...d the reader LED is orange as the reader goes into Configuration mode 2 Within 30 seconds while the reader is still in Configuration mode present a valid configuration card to the reader If the config...

Страница 16: ...t fully transmitted only the LSB portion of the serial number is transmitted This depends on the reader transmit format of the selected reader and the length of the card serial number For example when...

Страница 17: ...by the reader configurations These settings can be overridden using the brown LED buzzer control wire LED buzzer control wire is left open LED and buzzer behave naturally on the basis of firmware pre...

Страница 18: ...antle the unit or remove it from the wall The status of the tamper mechanism is indicated by the purple Tamper control wire When the back tamper optical sensor is in darkness status the internal tampe...

Страница 19: ...mission formats Refer to Section 5 5 for more information on selecting keypad transmission formats MIFARE cards presented to the reader are always sent in Wiegand or Clock Data format Refer to Section...

Страница 20: ...BCD Clock Data Single Key 2 Selecting MIFARE Card Transmission Format 1 Wiegand 26 Bit default 2 Clock Data 4 Wiegand 26 Bit with Facility code output 5 Wiegand 32 Bit 6 Wiegand 32 Bit reverse output...

Страница 21: ...ight LED turns red 2 Enter your 4 digit Programming code If the Programming code is valid the right LED turns green If the Programming code is invalid you hear a long beep and the reader returns to St...

Страница 22: ...LED turns red 3 Enter one of the following codes 1 Single Key Wiegand 6 Bit Rosslare Format default 2 Single Key Wiegand 6 Bit with Nibble Parity Bits 3 Single Key Wiegand 8 Bit Nibbles Complemented...

Страница 23: ...3 0 0011 1 9 1 1001 0 4 1 0100 1 1 1011 1 B in Hexadecimal 5 1 0101 0 0 1100 1 C in Hexadecimal Option 2 Single Key Wiegand 6 Bit Nibble and Parities Each key press immediately sends 4 bits with 2 par...

Страница 24: ...ctory default setting for the Facility code is 001 see Section 5 8 for more information The keypad PIN code must be 4 digits in length and can range between 0000 and 9999 On the fourth key press of th...

Страница 25: ...can range between 0 and 65 535 When entering a keypad PIN code that is less than 5 digits in length must be pressed to signify the end of PIN code entry For keypad PIN codes that are 5 digits in leng...

Страница 26: ...umber The keypad PIN code must be 6 key presses long On the sixth key press of the 6 digit PIN code and are valid the data is sent across the Wiegand Data lines as a BCD message If the entry of the 6...

Страница 27: ...two data output lines as binary data in Clock Data format If or is pressed during PIN code entry the keypad clears the PIN code entry buffer generates a beep and is ready to receive a new keypad PIN...

Страница 28: ...gramming mode 2 Press 2 to enter Menu 2 The left LED turns red 3 Enter the appropriate option number for the Rosslare proximity card transmission format 1 Wiegand 26 Bit 2 Clock Data 3 Wiegand Card PI...

Страница 29: ...data Option 2 Clock Data In this mode 4 bytes of card serial number are transmitted in Clock Data format Option 3 Wiegand Card PIN Transmission Format This unique format is intended to let host contr...

Страница 30: ...e A 2 bytes code generated from card serial number The third and fourth bytes of the cards serial number is not transmitted Option 5 Wiegand 32 Bit In this mode 4 bytes of card serial number are trans...

Страница 31: ...here EP Even parity for first 16 data bits OP Odd parity for last 16 data bits A 4th MSB byte of card serial number B 3rd byte of card serial number C 2nd byte of card serial number D 1st LSB byte of...

Страница 32: ...he left LED turns red 3 Enter the new 4 digit code you wish to set as the Programming code You hear three beeps The system returns to Standby mode 5 8 Changing the Facility Code The default Facility c...

Страница 33: ...off left LED also goes off 3 Backlight is dimmed activates for 10 seconds when a key is pressed left LED also goes on after which it returns to a dimmed level You hear three beeps The system returns t...

Страница 34: ...reader returns to Standby mode without erasing the memory of the reader 5 11 Replacing a lost Programming Code In the event that the Programming code is forgotten the unit may be reprogrammed in the...

Страница 35: ...mA maximum sink current Operational Characteristics Maximum Controller Cable Distance 150 m 500 ft using 18 AWG cable Proximity Read Range 20 mm 0 8 in Operating Frequency 13 56 MHz Transfer Bit Rate...

Страница 36: ...Characteristics Operating Temp Range 31 C to 63 C 25 F to145 F Operating Humidity Range 0 to 95 non condensing Operating Environment Suitable for outdoor use IP65 compliant water resistant Physical Ch...

Страница 37: ...37 A Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this produ...

Страница 38: ...a rosslaresecurity com Europe Rosslare Israel Ltd 22 Ha Melacha St P O B 11407 Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin Ame...

Отзывы: