Installation
AC-F/G4x Family Installation and Programming Manual
15
3.2
Wiring the Controller
The controllers are provided with a one-meter, pre-wired, 10-
conductor 18-AWG cable.
To wire the controller:
1.
Cut and strip the conductors to the necessary length.
2.
Splice the controller pigtail wires to the corresponding ancillary
devices and insulate each connection, including unused wires.
3.
Refer to Table 1 and to the wiring diagrams, depending on the
desired application:
Wiring the Lock Strike Relay & REX (Figure 4)
Wiring for Auxiliary Input & Output (Figure 5)
Wiring for the BL-D40 External Sounder (Figure 6)
Table 1: Wiring Color Guide
Color
Description
Red
V input
Black
Ground
Green
REX / BL
White
In / Monitor
Purple
Lock: Com
Gray
Lock: N.O.
Brown
Lock: N.C.
Blue
Aux: Com
Yellow
Aux: N.O.
Orange
Aux: N.C.