Input and Output Connections
AC-225 Hardware Installation and User Guide
Page 25
When using the MD-D02, the following should be defined:
Double door controller:
(each door has two
readers)
Reader1 – Door 1 IN/OUT
Reader2 – Door 1 OUT/IN
Reader3 – Door 2 IN/OUT
Reader4 – Door 2 OUT/IN
Four door controller:
(each door has one reader)
Reader1 – Door 1 IN/OUT
Reader2 – Door 2 IN/OUT
Reader3 – Door 3 IN/OUT
Reader4 – Door 4 IN/OUT
Use the AxTrax AS-525 software to set the readers for IN or OUT use and to
set the data transmission format for each reader.
The reader’s tamper output connects to the access control panel's
Reader-Tamper input. If the reader is interfered with, an alarm can be
generated.
The panel's Reader G.LED output activates the reader’s green LED input
when operating in "Card and PIN" secure mode. While this mode is in
force, users must enter a PIN on the keypad immediately after entering
the card.
The controller activates the LED control for 2 seconds when an access
granted event occurs.