Cable Type Selection
Use the following figure, card labeling, and discussions to set up VEA-7007A cable type selection
jumpers.
JP6 & JP7:
Cable Type Selection
Figure 2. VEA-7007A Jumper Locations
Set jumpers
JP6
and
JP7
to select the input cable type being equalized. The two jumpers must
both
be positioned at the same selections: (Belden)
8281
,
1694
, or
1505
. For other cable-types, choose the
closest matching cable type from these three selections.
Board Installation
Use the following steps to install the VEA-7007A cards in a RossGear 7200 series Video, or 7850
series A/V distribution frame:
1. Refer to the User Manual of the RossGear frame to ensure that the frame is properly
installed according to instructions. If this module is to be installed in any compatible
frame other than a Ross Video product, refer to the frame manufacturer’s manual for
specific instructions.
2. Please note that heat and power distribution requirements within a frame may dictate
specific slot placement of cards. Cards with many heat-producing components
should be arranged to avoid areas of excess heat build-up, particularly in frames
using convectional cooling.
3. After selecting the desired frame installation slot, hold the VEA-7007A card by the
edges and carefully align the card edges with the slots in the frame. Then fully insert
the card into the frame until the rear connection plug is properly seated.
2-2
•
Installation and Setup
VEA-7007A User Manual (Iss. 01)
Содержание VEA-7007A
Страница 6: ...ii Contents VEA 7007A User Manual Iss 01...
Страница 10: ...1 4 Introduction VEA 7007A User Manual Iss 01...
Страница 14: ...2 4 Installation and Setup VEA 7007A User Manual Iss 01...