Installation and Cabling
4843DR-200-01
© 2021 Ross Video Limited. Ross®, Carbonite, Ultrix, Ultripower, and any related marks are trademarks or registered trademarks of Ross Video Limited. All other trademarks are the property of their respective companies. PATENTS ISSUED and PENDING. All rights reserved. No
part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, mechanical, photocopying, recording or otherwise, without the prior written permission of Ross Video. While every precaution has been taken in the
preparation of this document, Ross Video assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
ENET 1
ENET 2
REF
AUX A AUX B
A
B
1
4
Ultrix-HDBNC-IO
AUX A AUX B
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
ENET 1
ENET 2
REF A
LOOP
TERM
A
B
REF B
ALARM
FLEX
SLOT
PWR
1
2
3
4
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-UCCI
StatusPrim/SecAlarm Aux
1
2
OUT
4
3
RESTART
ETHERNET
RESET
Ultripower - Ultrix
1
2
OUT
4
3
RESTART
ETHERNET
RESET
Ultripower - Carbonite
Ultrix 5RU Frame
SDPE (Software Defined Production Engine)
CAUTION!
Before you set up and operate your device, see the
“Important Safety Instructions” in your swicther and router manuals.
Power and Cabling
5
ENET
1
2
3
4
6
PWR 1 NO C NC
ALARM
PWR 2
7
8
Connect
external
reference
Connect video
inputs as
needed
(sources)
Connect video
outputs as
needed
(destinations)
Mains
Power
Notes:
• The Ultrix 5RU and 2RU frames support multiple Carbonite
switcher platforms at once.
• The switcher uses the Reference input to Ultrix for timing.
• All power supplies must be connected to operate the switcher.
• The input and output BNCs on the SDPE blade are mapped to
physical inputs and outputs 19-22 on the switcher.
• Physical sources and destinations on the router must be mapped
internally to inputs and outputs on the switcher.
• The Ultrix SDI I/O blade is used to provide sources and
destinations that the switcher can access.
• The REF B connection is not supported at this time.
• A 1GbE ethernet connection is required for Ultrix.
• An Ultricool may be required, depending on your installation.
• The Ultra 5RU frame can support up to 4 SDPE blades and the
2RU can support up to 2 SDPE blades.
Notes:
• The switcher is made up of a single SDPE blade. Each SDPE blade provides an independent Carbonite switcher.
• The number of SDPE blades a system can have depends on the size of the Ultrix frame and the other blades that
are installed.
• Each SDPE blade is independent of the others. If you upgrade one to a different version of software, that upgrade
is not pushed to the other SDPE blades.
• There should be a 1-slot gap between SDPE blades in either ther 5RU or 2RU router to ensure proper cooling. An
I/O blade can be installed in that gap, but two SDPE blades should not be installed next to each other.
• The GPI and Tally ports on each SDPE blade are independent of each other.
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
GPI I/O
Tally
AES
LTC
Serial
Network
USB
Power
DIP
Switches
SDPE
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
SD
PWR
SDPE
ETHERNET
EDITOR
AES1
AES2
LTC
TALLY
GPIO
OUTPUT
INPUT
1
2
3
4
1
2
3
4
1 2 3 4
8-10in-lbs
UPGD
ENET 1
ENET 2
REF A
LOOP
TERM
A
B
REF B
ALARM
FLEX
SLOT
PWR
1
2
3
4
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-HDBNC-IO
AUX A AUX B
Ultrix-UCCI
StatusPrim/SecAlarm Aux
Ultrix 5RU
Ultrix 2RU
Aux SFP+
Aux SFP+
Ref In
SDPE
SDPE
Ultrix SDI I/O
Ultrix SDI I/O
Reference
In/Loop
Input BNCs
Output BNCs
Input BNCs
Output BNCs
Slot 1
Flex Slot
Slot 2
Slot 3
Slot 4
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
GPI I/O
(female DB25)
1
2
3
4
5
6
7
8
9
10
11
12
13
Pin
Pin
GPI I/O 1
GPI I/O 2
GPI I/O 3
GPI I/O 4
GPI I/O 5
GPI I/O 6
GPI I/O 7
GPI I/O 8
GPI I/O 9
GPI I/O 10
GPI I/O 11
GPI I/O 12
GPI I/O 13
Signal
Signal
14
15
16
17
18
19
20
21
22
23
24
25
GPI I/O 14
GPI I/O 15
GPI I/O 16
GPI I/O 17
GPI I/O 18
GPI I/O 19
GPI I/O 20
GPI I/O 21
GPI I/O 22
GPI I/O 23
GPI I/O 24
Ground
Tally
(female DB25)
1
2
3
4
5
6
7
8
9
10
11
12
13
Pin
Pin
Tally 1
Tally 2
Tally 3
Tally 4
Tally 5
Tally 6
Tally 7
Tally 8
Tally 9
Tally 10
Tally 11
Tally 12
Tally 13
Tally
Tally
14
15
16
17
18
19
20
21
22
23
24
25
Tally 14
Tally 15
Tally 16
Tally 17
Tally 18
Tally 19
Tally 20
Tally 21
Tally 22
Tally 23
Tally 24
Common
AES-
AES+
GND
LTC-
LTC-
LTC+
Read the instruction manual for your Ultripower and Ultrix FR5 or Ultrix FR2 before
starting work or operating equipment.
NOTICE
The Ultrix frame and SDPE blades do not have power switches. Ensure that
the Ultripower is not connected to mains power before connecting the power cables
from the Ultripower to the other components. If the Ultripower is energized as you
connect the power cables to the Ultrix and SDPE, the system could start to power up
before it has enough power to operate and could damage the equipment.
NOTICE
Adequate ventilation within a rack
frame must be maintained. Ensure side to side
ventilation is not compromised. Refer to the
Ultrix Installation Guide for more information.
CAUTION!
Electrical shock hazard. The Power connector (PWR) must
always be disconnected when the SDPE blade is not installed in the frame.
Note:
Terminate the REF LOOP connector
and set the DIP to TERM if the router is the
last device in the reference chain.
Note:
Ensure that the end
of the power cable with the
ferrite bead is connected to
the Ultripower.
To
DashBoard
Ultricool (optional)
Ethernet
1GbE
Input
BNCs
Output