Ross Ultrix Carbonite Скачать руководство пользователя страница 1

Installation and Cabling

4843DR-200-01

© 2021 Ross Video Limited. Ross®, Carbonite, Ultrix, Ultripower, and any related marks are trademarks or registered trademarks of Ross Video Limited. All other trademarks are the property of their respective companies. PATENTS ISSUED and PENDING. All rights reserved. No 

part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, mechanical, photocopying, recording or  otherwise, without the prior written permission of Ross Video. While every precaution has been taken in the 

preparation of this document, Ross Video assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

ENET 1

ENET 2

REF

AUX A AUX B

A

B

1

4

Ultrix-HDBNC-IO

AUX A AUX B

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

ENET 1

ENET 2

REF A

LOOP

TERM

A

B

REF B

ALARM

FLEX

SLOT

PWR

1

2

3

4

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-UCCI

StatusPrim/SecAlarm Aux

1

2

OUT

3

RESTART 

ETHERNET

RESET 

Ultripower - Ultrix

1

2

OUT

3

RESTART 

ETHERNET

RESET 

Ultripower - Carbonite

Ultrix 5RU Frame

SDPE (Software Defined Production Engine)

CAUTION!

 

Before you set up and operate your device, see the 

“Important Safety Instructions” in your swicther and router manuals.

Power and Cabling

5

ENET

1

2

3

4

6

PWR 1 NO C NC

ALARM

PWR 2

7

8

Connect 

external 

reference

Connect video 

inputs as 

needed

(sources) 

Connect video 

outputs as 

needed

(destinations) 

Mains 

Power

Notes: 

 •  The Ultrix 5RU and 2RU frames support multiple Carbonite 

switcher platforms at once.

 •  The switcher uses the Reference input to Ultrix for timing.
 •  All power supplies must be connected to operate the switcher.
 •  The input and output BNCs on the SDPE blade are mapped to 

physical inputs and outputs 19-22 on the switcher.

 •  Physical sources and destinations on the router must be mapped 

internally to inputs and outputs on the switcher. 

 •  The Ultrix SDI I/O blade is used to provide sources and 

destinations that the switcher can access.

 •  The REF B connection is not supported at this time.
 •  A 1GbE ethernet connection is required for Ultrix.
 •  An Ultricool may be required, depending on your installation.
 •  The Ultra 5RU frame can support up to 4 SDPE blades and the 

2RU can support up to 2 SDPE blades.

Notes: 

 •  The switcher is made up of a single SDPE blade. Each SDPE blade provides an independent Carbonite switcher. 
 •  The number of SDPE blades a system can have depends on the size of the Ultrix frame and the other blades that 

are installed.

 •  Each SDPE blade is independent of the others. If you upgrade one to a different version of software, that upgrade 

is not pushed to the other SDPE blades.

 •  There should be a 1-slot gap between SDPE blades in either ther 5RU or 2RU router to ensure proper cooling. An 

I/O blade can be installed in that gap, but two SDPE blades should not be installed next to each other.

 •  The GPI and Tally ports on each SDPE blade are independent of each other.

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

GPI I/O

Tally

AES

LTC

Serial

Network

USB

Power

DIP

Switches

SDPE

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

SD

PWR

SDPE

ETHERNET

EDITOR

AES1

AES2

LTC

TALLY

GPIO

OUTPUT

INPUT

1

2

3

4

1

2

3

4

1 2 3 4 

8-10in-lbs

UPGD

ENET 1

ENET 2

REF A

LOOP

TERM

A

B

REF B

ALARM

FLEX

SLOT

PWR

1

2

3

4

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-HDBNC-IO

AUX A AUX B

Ultrix-UCCI

StatusPrim/SecAlarm Aux

Ultrix 5RU

Ultrix 2RU

Aux SFP+

Aux SFP+

Ref In

SDPE

SDPE

Ultrix SDI I/O

Ultrix SDI I/O

Reference

In/Loop

Input BNCs

Output BNCs

Input BNCs

Output BNCs

Slot 1

Flex Slot

Slot 2
Slot 3
Slot 4

Slot 1
Slot 2
Slot 3
Slot 4

Slot 5
Slot 6
Slot 7
Slot 8

GPI I/O

(female DB25)

1

2

3

4

5

6

7

8

9

10

11

12

13

Pin

Pin

GPI I/O 1

GPI I/O 2

GPI I/O 3

GPI I/O 4

GPI I/O 5

GPI I/O 6

GPI I/O 7

GPI I/O 8

GPI I/O 9

GPI I/O 10

GPI I/O 11

GPI I/O 12

GPI I/O 13

Signal

Signal

14

15

16

17

18

19

20

21

22

23

24

25

GPI I/O 14

GPI I/O 15

GPI I/O 16

GPI I/O 17

GPI I/O 18

GPI I/O 19

GPI I/O 20

GPI I/O 21

GPI I/O 22

GPI I/O 23

GPI I/O 24

Ground

Tally

(female DB25)

1

2

3

4

5

6

7

8

9

10

11

12

13

Pin

Pin

Tally 1

Tally 2

Tally 3

Tally 4

Tally 5

Tally 6

Tally 7

Tally 8

Tally 9

Tally 10

Tally 11

Tally 12

Tally 13

Tally

Tally

14

15

16

17

18

19

20

21

22

23

24

25

Tally 14

Tally 15

Tally 16

Tally 17

Tally 18

Tally 19

Tally 20

Tally 21

Tally 22

Tally 23

Tally 24

Common

AES-

AES+

GND

LTC-

LTC-

LTC+

Read the instruction manual for your Ultripower and Ultrix FR5 or Ultrix FR2 before 

starting work or operating equipment.

NOTICE

 The Ultrix frame and SDPE blades do not have power switches. Ensure that 

the Ultripower is not connected to mains power before connecting the power cables 

from the Ultripower to the other components. If the Ultripower is energized as you 

connect the power cables to the Ultrix and SDPE, the system could start to power up 

before it has enough power to operate and could damage the equipment.

NOTICE

 Adequate ventilation within a rack 

frame must be maintained. Ensure side to side 

ventilation is not compromised. Refer to the 

Ultrix Installation Guide for more information.

CAUTION!

 Electrical shock hazard. The Power connector (PWR) must 

always be disconnected when the SDPE blade is not installed in the frame. 

Note:

 Terminate the REF LOOP connector 

and set the DIP to TERM if the router is the 

last device in the reference chain.

Note:

 Ensure that the end 

of the power cable with the 

ferrite bead is connected to 

the Ultripower.

To 

DashBoard

Ultricool (optional)

Ethernet

1GbE

Input

BNCs

Output

BNCs