Ross Ultripower Скачать руководство пользователя страница 1

Ultripower User Guide

Содержание Ultripower

Страница 1: ...Ultripower User Guide...

Страница 2: ...eople that make things happen At Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethics...

Страница 3: ...manual Trademarks Google is a registered trademark of Google Inc Microsoft Excel and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation in the United States and...

Страница 4: ...ular purpose are expressly limited to the duration of this warranty This warranty is TRANSFERABLE to subsequent owners subject to Ross notification of change of ownership Environmental Information The...

Страница 5: ...O Box 880 Ogdensburg New York USA 13669 0880 General Business Office 1 613 652 4886 Fax 1 613 652 4425 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail Technical Support t...

Страница 6: ......

Страница 7: ...ork 16 Connecting an Ultrix Router to Ultripower 16 Connecting to an ULTRIX FR1 Router 16 Connecting to an ULTRIX FR2 Router 17 Connecting to an ULTRIX FR5 Router 18 Connecting to a Power Source 19 Co...

Страница 8: ...Control Tab 30 Log Tab 31 Setup Tab 31 Network Tab 32 Maintenance 33 Installing a PSU Module 33 Removing a Blank Module Plate from the Ultripower Chassis 33 Removing the PSU Module from the Ultripowe...

Страница 9: ...e from the chassis removing a PSU module from the chassis and installing a new PSU module Technical Specifications provides the specifications such as dimensions and power consumption for the Ultripow...

Страница 10: ...s Video we take pride in the quality of our products but if problems occur help is as close as the nearest telephone Our 24 hour Hot Line service ensures you have access to technical expertise around...

Страница 11: ...d as a positive power rail supply Supported Devices The Ultripower supports the following Ross devices ULTRIX FR1 ULTRIX FR2 ULTRIX FR5 Features The Ultripower includes the following features 1200W ou...

Страница 12: ...1 1 4 A B REF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 AUX A AUX B OUT IN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 AUX A AUX B...

Страница 13: ...3 Slot 2 Power Supply Module The Slot 2 Power Supply Module provides power to the four DC outputs If a PSU module is present and operating in Slot 1 the load is distributed between the operating modu...

Страница 14: ...10 00 Ethernet Port The Ethernet port is an RJ45 connector used to connect the Ultripower to an external Ethernet network This port is required for monitoring and control of Ultripower 4 Reset and Res...

Страница 15: ...in the correct warranty service procedures We recommend that the equipment is installed by qualified and experience personnel to any relevant standards and approvals Mounting Requirements The Ultripow...

Страница 16: ...tact your network administrator To establish a physical connection to the network 1 Connect one free end of a standard CAT 5 5e 6 Ethernet cable to a free port of the network hub 2 Connect the other e...

Страница 17: ...e end with the ferrite bead connects to the Ultripower port Figure 4 2 Notice The ULTRIX FR2 requires a minimum of two power supply connections Notice Ensure that the power cable end with the ferrite...

Страница 18: ...ct an AC power cable to the Ultripower PSU 1 socket 4 If Ultripower is fitted with a second power module connect a second AC power cable to the Ultripower PSU 2 socket Notice The ULTRIX FR2 router aut...

Страница 19: ...supply cord Use only certified cords for the country of use REF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 OUT IN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7...

Страница 20: ...the socket marked A on the Ultripower rear panel Figure 4 5 Ultripower Power Connections 2 Connect the remaining power cable into the socket marked B 3 Connect the supplied AC power cable into the po...

Страница 21: ...ct File Show Walkabout The DashBoard window displays the Walkabout table 3 Click Refresh located at the bottom of the Walkabout tab to ensure the list in the Walkabout interface is current 4 In the Wa...

Страница 22: ...ess field that you assigned in the section To assign the initial static IP address for the Ultripower on page 21 7 Perform one of the following steps In the text fields provided enter the display name...

Страница 23: ...ss the Ultripower To add a DashBoard client to the Ultripower DB Whitelist 1 Display the Ultripower interface in DashBoard as outlined in the procedure To access the Database interfaces in DashBoard o...

Страница 24: ...el to a physical Output Port on the Ultripower chassis Some external devices require multiple ports e g ULTRIX FR5 requires four ports Refer to the user guide for your external device to confirm the n...

Страница 25: ...Ultripower User Guide v4 0 Configuration 25 7 Click Yes The Confirm dialog closes and power is enabled to that device...

Страница 26: ...26 Configuration Ultripower User Guide v4 0...

Страница 27: ...Monitoring via the Rear Panel LEDs The Ultripower rear panel includes LEDs on the ETHERNET RJ45 port Figure 6 1 Figure 6 1 ETHERNET Port LEDs Table 6 1 Front Panel Power Supply Module LEDs LED Status...

Страница 28: ...ect the Alarm on missing PSU check box To view the status of a PSU slot via DashBoard 1 Locate the Ultripower in the Tree View of DashBoard 2 Expand the Ultripower node 3 Double click the Ultripower s...

Страница 29: ...orts the most severe alarm for a single field Alarm colors are noted within the tables as text set in brackets next to the menu parameter name Product Tab Table 7 1 summarizes the read only informatio...

Страница 30: ...area network LAN Active Connections Indicates the total number of active DashBoard client connections to this unit Table 7 3 PSU Tab Item Parameters Description PSU Slot Status OK Green Ultripower is...

Страница 31: ...the device power state Table 7 5 Log Tab Message Description Outx overcurrenta a Where x is output 1 to 4 the device connected to output port x is drawing too much current Outx undervoltage the outpu...

Страница 32: ...name to the device This name also displays in the DashBoard tree view The default is Ultripower IP Address Specifies the IP address for the Ultripower The default is 192 168 20 123 Subnet Mask Specifi...

Страница 33: ...er Chassis on page 34 Removing the PSU Module from the Ultripower Chassis Each PSU Module is accessed via the front of the Ultripower chassis and requires that you loosen the two retaining bolts secur...

Страница 34: ...following procedure is applicable to any PSU Module slot To install a new PSU module into the chassis 1 Align the new PSU module into the slot inside the chassis 2 Gently slide the new PSU module into...

Страница 35: ...nvironmental Table 9 1 Physical Dimensions Item Specifications Width not including rack mounting ears 17 5 444 5mm Depth chassis only 8 1 206mm Height 1 7 43 2mm Weight approx Chassis 1PSU 3 24kg 7 14...

Страница 36: ...36 Technical Specifications Ultripower User Guide v4 0...

Отзывы: